TIE DOWN 72810 Скачать руководство пользователя страница 14

14

TIE DOWN 

Safety Products Division

800-241-1806   •   404-344-0000  •  www.tiedown.com

E1847, Rev. 9/24/21

Tie Down Engineering, Inc. 
605 Stonehill Drive, SW

 

Atlanta, GA 30336

 

404-344-0000

 

[email protected] 
www.tiedown.com

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DECLARATION OF CONFORMITY

 

Declaration Date: 08.11.2021 

Rev. 0

 

 

 

 

 

TIE DOWN ENGINEERING 

DECLARES THAT THE PRODUCT(S) LISTED ABOVE IS IN 

CONFORMITY WITH THE REQUIREMENTS OF THE FOLLOWING PERFORMANCE 

STANDARDS. 

 

STANDARD(S): 

 

 

OSHA 1926 Fall Protection Criteria 

 

OSHA 1910 Personal Fall Protection Systems 

 

 
*** This certificate declares that the above standard(s) was met by the requirements of such standard(s). 

Testing was performed under normal operating measures. The results of testing apply only to the sample(s) 

tested and to the specific test(s) performed. This certificate is only issued for products which have passed 
the testing requirements of the standard(s) listed. The end-user is responsible for using the product(s) for 

its intended purpose(s) only and must review all manuals and instructional documentation prior to use. *** 

 

 

 

DECLARATION NO. 

ETR-72810, 72841_R0 

PART NUMBER(S): 

72810, 72841 

PART DESCRIPTION: 

Penetrator X3 Cart (PX3) 

ADDITIONAL INFORMATION REGARDING THIS DOCUMENT OR STANDARD(S) EVALUATED: 

 

 

Содержание 72810

Страница 1: ...Nickel which is known to the State of California to cause cancer For more information go to www P65Warnings ca gov WARNING This product can expose you to chemicals including Nickel which is known to t...

Страница 2: ...Separately Rescue Winch Assembly Purchased Separately Mounting Pins Mounting Frame Spike Engagement Tube Tension Spring Retainer Penetrator Spikes 800 241 1806 404 344 0000 www tiedown com PX3 Fall A...

Страница 3: ...ss connectors and a body harness and must include a deceleration system or suitable combinations Note that a PFAS does NOT prevent a fall from occurring The Penetrator X3 can be used as an anchorage i...

Страница 4: ...UIREMENTS Verify that the surface that the Penetrator X3 will be used on is capable of supporting both the unit and personnel using it Inspect that the entire area to determine if the working surfaces...

Страница 5: ...t Path Cart Path 8 ft Min 15 ft 45 45 45 45 Unprotected Edge or Leading Edge 16 Feet Safe Work Zone Unprotected Edge or Leading Edge 30 Feet Maximum Safe Work Zone After 15 feet the maximum Range of U...

Страница 6: ...equipped with lanyards harnesses safety lines etc when working in conjunction with potential fall arrest workers Do not attached fall restraints to the hoisting ring locations Do Not allow the fall re...

Страница 7: ...X3 should not be used by persons whose ability or alertness is impaired by fatigue intoxicating beverages illegal or prescription drugs or any other physical cause that exposes the user or others to...

Страница 8: ...the rigging gear DO NOT hook to the fall arrest or fall restrain shackle safety line connectors when lifting the cart 3 1 2 Carriage Bolts Install the Permanent Winch Mount From the back side of the P...

Страница 9: ...d to use a 1 2 impact wrench for this part of the installation There are two options for installing the permanent roller guide bracket assembly 1 Access the nylock nut by working from the top inside a...

Страница 10: ...cue hook should pass under the roller and about the bottom of the roller bracket WARNING Be careful not to come in contact with the five penetrating spikes 3 1 4 Clevis Pin 3 1 2 Carriage Bolts Safety...

Страница 11: ...A WORKER WHEN NOT BEING PROPERLY CONNECTED TO AN APPROVE ANCHORAGE CONNECTION CAN RESULT IN SERIOUS INJURY INCLUDING DEATH Workers must be properly trained in the use of the Tie Down Rescue System PR...

Страница 12: ...d off to the Penetrator X3 Using a rescue pole attach the hook cable to the fallen worker If the cable length and ground conditions allow it is recommended to lower the worker safely to the ground If...

Страница 13: ...deployment as the result of an fall incident make certain that the rescue procedure has been successfully completed The five penetrating spikes will be somewhat buried into the roof after activation F...

Страница 14: ...tems This certificate declares that the above standard s was met by the requirements of such standard s Testing was performed under normal operating measures The results of testing apply only to the s...

Страница 15: ...on the employee to 1 800 pounds 8 kN 1910 140 d 1 ii Bring the employee to a complete stop and limit the maximum deceleration distance the employee travels to 3 5 feet 1 1 m 1910 140 d 1 iii Have suff...

Страница 16: ...l Cart Parts Date Corrective Action Taken Penetrator X3 Device Frame Free of Rust Frame Welded Connections Mounting Pins 2 Penetrator X3 Spikes Free of Damage Spike Guard Shield Present Anchor Shackle...

Отзывы: