TIDE and Tibbo BASIC User Manual
©2000-2008 Tibbo Technology Inc.
PL_IO_NUM_22_INT6:
Selects general-purpose I/O line 22 (P2.6).
PL_IO_NUM_23_INT7:
Selects general-purpose I/O line 23 (P2.7).
PL_IO_NUM_24:
Selects general-purpose I/O line 24 (does not belong to
any 8-bit port).
PL_IO_NUM_25:
Selects general-purpose I/O line 25 (does not belong to
any 8-bit port).
PL_IO_NUM_26:
Selects general-purpose I/O line 26 (does not belong to
any 8-bit port).
PL_IO_NUM_27:
Selects general-purpose I/O line 27 (does not belong to
any 8-bit port).
PL_IO_NUM_28:
Selects general-purpose I/O line 28 (does not belong to
any 8-bit port).
PL_IO_NUM_29_CO:
Selects general-purpose I/O line 29 (does not belong to
any 8-bit port). This line is also used by the
object to generate square wave output that is primarily
intended for driving beeper (buzzer).
PL_IO_NUM_30:
Selects general-purpose I/O line 30 (does not belong to
any 8-bit port).
PL_IO_NUM_31:
Selects general-purpose I/O line 31 (does not belong to
any 8-bit port).
PL_IO_NULL:
This is a NULL line that does not physically exist.
The state of this line is always detected as LOW.
Setting this line has no effect.
Notes:
1. When a serial port is in the
mode (
= 0-
PL_SER_MODE_UART) this line is automatically configured to be an input when
this serial port is enabled (
= 1- YES) and returns to the previous
input/output and high/low state when this serial port is closed (ser.enabled= 0-
NO). When a serial port is in the
mode (ser.mode=
1- PL_SER_MODE_WIEGAND or ser.mode= 2- PL_SER_MODE_CLOCKDATA), the
line has to be configured as input by the application- this will not happen
automatically.
2. When a serial port is in the UART mode (ser.mode= 0- PL_SER_MODE_UART)
this line is automatically configured to be an output when the serial port is
enabled (ser.enabled= 1- YES) and returns to the previous input/output and
high/low state when the serial port is closed (ser.enabled= 0- NO). When a
serial port is in the Wiegand or clock/data mode (ser.mode= 1-
PL_SER_MODE_WIEGAND or ser.mode= 2- PL_SER_MODE_CLOCKDATA), the
line has to be configured as output by the application- this will not happen
automatically.
3. When the beeper pattern stars playing, this line is configured as output
automatically. When the beeper pattern stops playing, the output returns to the
input/output and high/low state that it had before the pattern started playing.