background image

© 2016 Thorlabs GmbH

2 Technical Data

7

MTD415T Data Sheet Rev. 1.0

2.3   Electrical Characteristics

TEC Current Output

Output Current

up to ±1.5 A into 2.66 

W

 TEC - see diagram on 

page

.

Compliance Voltage

4.0 V

Output Power

up to 6.0 W

Measurement Resolution

better than 8 mA, typ. 3 mA

Measurement Accuracy

± 50 mA

Noise and Ripple (typ.)

< 10 mA 

1

)

TEC Current Limit

Setting Range

0 to 1.5 A

Setting Resolution

1 mA

Setting Accuracy

± 50 mA

Temperature Sensor

Supported Sensor

10 k

W

 Thermistor 

5

)

Maximum Temperature Control Range 

2

)

+ 5 °C to + 45 °C

Temperature Setting Resolution

1 mK

Temperature Measurement Resolution 

3

)

better than 10 mK; typ. 2 mK

Absolute Temperature Accuracy 

2

)

± 0.5 °C

Temperature Stability over 8 h, typ.

better than 20 mK

Temperature Coefficient

< 20 mK/°C

Programming Interface

Type

UART

Voltage Level

3.3 V Logic Level; input 5 V tolerant

Data Rate

115.200 bps; 8 Data Bits, 1 Stop Bit

General Data

Safety Features

·

TEC Current Limit

·

Sensor Fault Protection

·

TEC Open Circuit Protection

·

Temperature Setpoint Limit

·

Temperature Window Protection Delay

·

Over Temperature Protection

Operating Temperature

-20 °C to +60 °C 

4

)

Storage Temperature 

-40 °C to +100 °C 

4

)

Warm-Up Time for Rated Accuracy

10 min

Dimensions (W x H x D)

21 x 12.4 x 3.1 mm³

Approx. Weight

 2 g

1

) Measured with a TEC element with an equivalent resistance of 4 

W

.

2

) Control range and thermal stability depend on thermistor parameters.

3

) Maximum measurement resolution depends on cycle time settings. Please refer to Programmers Reference.

4

) non-condensing

5

) Use only thermistors with 10k

W

 resistance at 25 °C (R

25°C

). Resistance Measurement Range: 4.2 to 29 k

W

All technical data are valid at 23 ±5 °C and 45 ±15% rel. humidity (non condensing)

8

Содержание MTD415T

Страница 1: ...ghly integrated temperature controller optimized for use in high performance thermoelectric temperature control applications The on chip power stage and the thermal control loop circuitry minimize ext...

Страница 2: ...Revision History Revision Changes with respect to previous revision 1 0 Initial Release 2 MTD415T Data Sheet Rev 1 0 MTD415T...

Страница 3: ...Typical Application 6 12 Programmers Reference 12 6 1 Nomenclature 12 6 2 Command Description 12 6 2 1 General Commands 13 6 2 2 TEC Commands 14 6 2 3 Temperature 15 6 2 4 Control Loop 17 6 2 5 Save S...

Страница 4: ...rence Output Voltage for Thermistor Temperature Sensor Connect this reference voltage output 1 8 V to one end of the 10 kW thermistor 7 TEMP Thermistor Temperature Sensor Input Connect this pin to the...

Страница 5: ...Asynchronous Data Input Connect this pin to the TX pin of your application 14 GND Supply Voltage Ground Connect the power supply ground connections to GND 15 TEC TEC Element negative connection Conne...

Страница 6: ...ure 40 C to 70 C 1 All voltages with respect to network ground terminal Notes 1 Above specifications are given for the free air operating temperature range unless otherwise noted 2 Stresses beyond tho...

Страница 7: ...cient 20 mK C Programming Interface Type UART Voltage Level 3 3 V Logic Level input 5 V tolerant Data Rate 115 200 bps 8 Data Bits 1 Stop Bit General Data Safety Features TEC Current Limit Sensor Faul...

Страница 8: ...esistance the maximum output current drops due to compliance voltage limitation 3 The maximum output current at lower than 2 66 W load resistance colored range depends on environmental conditions Note...

Страница 9: ...parator controls then the current of the thermoelectric cooler in order to maintain the temperature of the object constant Ideally the temperature settling is carried out in the shortest times with mi...

Страница 10: ...TEC current limit might be helpful for control loop optimization in case of low thermal loads and lowers the dissipated by the MTD415T power Micro controller The functions of the microcontroller are...

Страница 11: ...2016 Thorlabs GmbH 5 Typical Application 11 MTD415T Data Sheet Rev 1 0 5 Typical Application...

Страница 12: ...ion Response Example u Reads the UUID Universal Unique Identifier of the MTD415T 045F778655FDE5118ED499C9B4521485 Command Explanation Response Example E Reads the Error Register Responses see section...

Страница 13: ...gramming Lx Sets the TEC current limit to x Value range x 200 to 2000 mA Reading L Reads the TEC current limit x LF mA A Reads the actual TEC current x LF mA x 0 Heating x 0 Cooling U Reads the actual...

Страница 14: ...e Programming Wx Sets the set temperature window to x Value range x 1 to 32768 mK Reading W Reads the temperature window x LF mK Command Explanation Response Example Programming dx Sets the delay time...

Страница 15: ...critical period to x Value range x 100 to 100000 msec Reading O Reads the critical period x LF msec PID Settings Command Explanation Response Example Programming Cx Sets the cycling time to x Value r...

Страница 16: ...ue range x 0 to 100000 mA K sec Reading I Reads the I Share x LF mA K sec Command Explanation Response Example Programming Dx Sets the D Share to x Value range x 0 to 100000 mA s K Reading D Reads the...

Страница 17: ...ile memory 6 2 6 Factory Default Settings Parameter Explanation Factory Default L TEC current limit 1000 mA T Temperature set value 25 C W Temperature window 1000 mK d Temperature window delay 10 sec...

Страница 18: ...Latch Up TEC current at limit without temperature improvement 3 Cycling time too small 4 No Sensor detected 5 No TEC detected connection open 6 TEC mispoled 7 not used 8 not used 9 not used 10 not use...

Страница 19: ...ired error at the Status output pin Attention Masking an error may lead to damage of the MTD415T For example if bit 1 is masked exceeding the internal temperature will not be reflected on the status p...

Страница 20: ...s heat dissipation The D share differential share or the gain at high frequencies allows the system to quickly react to temperature changes without generating oscillation of the temperature around th...

Страница 21: ...he critical oscillation period O5580 5 The firmware calculates the parameters of the digital PID loop and applies them instantly The calculated parameters can be read out using the following commands...

Страница 22: ...rlabs Compatible Android apps are QR Barcode Scanner QRbot by TeaCapps This scanner allows to share the scanned code directly by email https play google com store apps details id net qrbot hl de QR Dr...

Страница 23: ...2016 Thorlabs GmbH 9 Drawing 23 MTD415T Data Sheet Rev 1 0 9 Drawing...

Страница 24: ...l AC Alternating Current DC Direct Current ESD Electrostatic discharges GND Ground GUI Graphic User Interface I C Inter Integrated Circuit C Micro Controller NTC Negative Temperature Coefficient therm...

Страница 25: ...ts the hard and or software determined by Thorlabs GmbH for this unit to operate fault free provided that they are handled according to our requirements However Thorlabs GmbH does not warrant a fault...

Страница 26: ...he purchase of this product In no event shall any liability exceed the purchase price of the product Please note that the content of this document is neither part of any previous or existing agreement...

Страница 27: ...of life take back service does not refer to other Thorlabs GmbH products such as pure OEM products that means assemblies to be built into a unit by the user e g OEM laser driver cards components mecha...

Страница 28: ...Scandinavia Thorlabs Sweden AB Bergfotsgatan 7 431 35 M lndal Sweden Tel 46 31 733 30 00 Fax 46 31 703 40 45 www thorlabs com Email scandinavia thorlabs com France Thorlabs SAS 109 rue des C tes 7860...

Страница 29: ......

Страница 30: ...www thorlabs com...

Отзывы: