Scanner
operation
Frequency of Texture Frames
This parameter indicates with what fre-
quency the recording of texture frames is
carried out. These frames are needed for
texturizing the final model. The lower the
parameter, the higher the frequency and
thereby the higher the amount of texture
frames recorded. Setting the parameter
at 0 will turn the textures off.
Reconstruction Sensitivity
If during scanning there is a lot of “noise”
on the screen that means that either the
object is very dark (black objects are gen-
erally more difficult to scan than those
of lighter colors) or there is too much
ambient light in the room. To correct this,
try adjusting this parameter.
Increasing the value will increase the “sensitivity”, allowing the scanner to see more data, but
also increasing the amount of “noise”. Decreasing the value, will decrease both. The default
value is set to 6.