THOR Salamander GL163-N Скачать руководство пользователя страница 3

2

 

 

Introduction 

 

 

We are confident that you will be delighted with your Thor Gas Salamander, and it will become a most 

valued appliance in your commercial kitchen. 
To ensure you receive the utmost benefit from your new Gas Salamander, there are two important things 
you can do. 

 

Firstly: 

 

Please read the instruction book carefully and follow the directions given.  The time taken will be well 

spent. 

 

Secondly: 

 

If you are unsure of any aspect of the installation, instructions or performance of your appliance, 
contact your dealer promptly.  In many cases a phone call could answer your question. 

 

CE Only: 

 

These instructions are only valid if the country code appears on the appliance.  If the code does not 
appear on the appliance, refer to the supplier of this appliance to obtain the technical instructions for 

adapting the appliance to the conditions for use in that country. 

 

 

 

 

WARNING: 

 

IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY 
DAMAGE, INJURY OR DEATH. 

 

READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR 
SERVICING THIS APPLIANCE. 

 

 

 

 

WARNING: 

 

INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS, ARE TO BE POSTED IN A PROMINENT 
LOCATION. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER. 

 

 

 

WARNING: 

 

GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF 
FIRE. 
• 

THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED. 

• 

IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO 

ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED. 

• 

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS 

OR ANY OTHER APPLIANCE. 

• 

DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION. 

 

 

 

CAUTION: 

THIS APPLIANCE IS; 

• 

FOR PROFESSIONAL USE 

• 

ONLY QUALIFIED SERVICE PERSONS ARE TO CARRY OUT INSTALLATION, SERVICING AND GAS CONVERSION 
OPERATIONS. 

• 

COMPONENTS HAVING ADJUSTMENTS PROTECTED BY THE MANUFACTURER SHOULD NOT BE ADJUSTED BY 
THE USER/OPERATOR. 

Содержание Salamander GL163-N

Страница 1: ...vice or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment Fourth Way Avonmouth...

Страница 2: ...arances Wall mounting Gas Connection Commissioning Operation 9 Operation Guide Description of Controls Lighting the Main Burner Racking system Cooking recommendation Cleaning and Maintenance 9 General...

Страница 3: ...CE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE WARNING INSTRUCTIONS T...

Страница 4: ...er Heat Input 3 8KW 3 8KW 3 8KW Heat Total 7 6KW 7 6KW 7 6KW Gas Connection BSP Male BSP Male BSP Male The burner operating pressure is to be measured at the gas control valve outlet test point with t...

Страница 5: ...4 Dimensions Dimensions for Gas Salamander Note gas salamander rack can load bearing 15kg 33 lb...

Страница 6: ...t any damage immediately to the carrier and distributor Report any deficiencies to the distributor who supplied the appliance Check that the available gas supply is correct to that shown on the rating...

Страница 7: ...lack plastic spacers to the top rear corners of the unit Leave them unscrewed by approximately 5 mm 3 Fit the two adjusting screws bolts into the nut inserts at the bottom rear corners of the unit The...

Страница 8: ...resists the breakdown action of LPG must be used on every gas line connection unless compression fittings are used WARNING DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES 5 Check all gas connectio...

Страница 9: ...burner operation Check the High Fire burner operation Check the Racking System operation b Ensure that the operator has been instructed in the areas of correct lighting operation and shutdown procedur...

Страница 10: ...ing the Main Burners z Racking System z Cooking Recommendations Description of Controls The salamander has individual heat controls for the left and right sides Select the desired heat level and allow...

Страница 11: ...IBLE MATERIAL WITHIN 600 MM OF THE FRONT COOKING ZONE WHEN THE APPLIANCE IS IN USE SYSTEMATICALLY CHECK AND CLEAN THE COOKING AREA PARTICULARLY THE GRILL RACK AND DRIP TRAY BEFORE LIGHTING THE BURNERS...

Страница 12: ...wool Always apply the cleaner when the salamander is cool and rub in the direction of the grain Crumb Drip Tray Empty and clean daily Periodic Maintenance NOTE All maintenance operations should only b...

Страница 13: ...Before leaving the converted installation 1 Check all gas connections for leakages using soapy water or other gas detecting equipment 2 Check the following functions in accordance with the operating i...

Страница 14: ...13 Explosion drawing...

Страница 15: ...14 Explosion drawing Spare Parts List...

Страница 16: ...15 Spare Parts List Continued...

Страница 17: ...Fourth Way Avonmouth Bristol BS11 8TB...

Отзывы: