background image

 

 

18

 

 

Spare Parts List 
 

 

NO. 

DESCRIPTION 

Part No

 

CODE 

GE559-P 

GE559-N 

26 

Front insulation  

01.15.1066416 

27 

Front cover 

01.05.1029294 

28 

Control panel-l 

01.05.1029293 

29 

Main pipe assembly 

06.05.1472745 

30 

L-connector 

01.18.1067451 

31 

Main burner injector/Orifice 

(for Natural Gas) - #185 

01.20.1068670 

 

Main burner injector/Orifice 

(for LPG) - #109 

01.20.1068671 

 

32 

Infrared burner 

01.03.1015139 

33 

Safety Gas Valve 

01.20.1068572 

34 

Thermocouple 

03.11.1250034 

35 

Manifold assembly 

01.24.1070916 

36 

Regulator  

01.22.1069526 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание GE559-N

Страница 1: ...the vicinity of this or any other appliances Keep the area free and clear of combustible WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or...

Страница 2: ...arances Assembly Gas Connection Commissioning Operation 10 11 Operation Guide Description of Controls Lighting the Main Burner Main burner air supply Cleaning and Maintenance 12 Initial cleaning Daily...

Страница 3: ...IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOCATION THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER WARNING GREAT CARE MUST BE TAKEN BY THE OPERATOR TO US...

Страница 4: ...rating 1 0 kPa 2 75 kPa 2 75kPa Minimum inlet supply pressure 1 13 kPa 2 75 kPa 2 75 kPa Gas Connection BSP Male BSP Male BSP Male The burner operating pressure is to be measured at the gas control va...

Страница 5: ...4 Dimensions Dimensions for Gas Salamander Minimum clearance from grease filter minimum 600mm Refer AS NZS5601 Gas Installations Note Gas Salamander rack can carry a load of up to 15KG 33 lbf...

Страница 6: ...Components having adjustments protected by the manufacturer are only to be adjusted by an authorized service agent They are not to be adjusted by the installation person Step 1 Unpacking Step 2a Inst...

Страница 7: ...appliance in its approximate working position In accordance with AS NZS5601 Gas Installations 5 All air for burner combustion is supplied from underneath the unit The legs must always be fitted and n...

Страница 8: ...m 600mm 750mm We recommend allowing a clearance of 100 mm on either side of the appliance to allow access to the side panels for servicing purposes Using the wall mounting accessories provided with th...

Страница 9: ...them unscrewed by approximately 5 mm Refer to Fig 2 A 3 Fit the two adjusting screws bolts into the nut inserts at the bottom rear corners of the unit These should protrude approximately 30 mm from t...

Страница 10: ...fixed ex factory for the gas type 3 Correctly locate the appliance into its final operating position and using a spirit level adjust the legs so that the unit is level and at the correct height 4 Con...

Страница 11: ...y of a thermo electric system which will shut off the gas supply to that burner in the event that the burner goes out so that un burnt gas is not expelled 1 Select the burner required depress and turn...

Страница 12: ...designed and installed hood will act as the heart of the ventilating system for the room or area in which the unit is installed and will leave the unit independent of changing draft conditions All val...

Страница 13: ...ticles left on the surface will rust and further spoil the appearance of the finish NEVER USE A WIRE BRUSH STEEL SOURCING PADS EXCEPT STAINLESS SCRAPPER FILE OR OTHER STEEL TOOLS Surfaces which are ma...

Страница 14: ...he left side panel and right side panel 3 Replace the burner injectors See the parts list or Gas Specification Table below 4 Adjust the gas supply pressure and convert the gas regulator 5 Change ratin...

Страница 15: ...Page 13 Only one burner in a unit produce excessive carbon deposits Incorrect injector orifice installed Ensure that a correct injector orifice is installed on the unit Refer to Gas Specification Tabl...

Страница 16: ...15 Explosion drawing 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 20 21 23 22 25 26 27 19 24...

Страница 17: ...16 Explosion drawing Continued 29 30 31 32 33 34 35 36...

Страница 18: ...05 1029298 1 1 10 Upper inner1 01 15 1066418 1 1 11 Top cover 01 05 1029295 1 1 12 Feet1 02 12 1165053 2 2 13 Back hold plate 01 15 1066412 1 1 14 Back panel 01 15 1066415 1 1 15 Back inner plate 01...

Страница 19: ...Main pipe assembly 06 05 1472745 2 2 30 L connector 01 18 1067451 2 2 31 Main burner injector Orifice for Natural Gas 185 01 20 1068670 2 Main burner injector Orifice for LPG 109 01 20 1068671 2 32 I...

Страница 20: ...15 Badgally Road Campbelltown NSW 2560 Thor after sales service 1300 225 960 V1 Rev4 12 20...