14

 

 

 

TROUBLESHOOTING  

 

Consult the following table: 

 

Problem 

Cause 

Remedy 

Burners in the unit will 
not turn “ON” 

Main gas supply to unit is “OFF” 

Ensure that the main gas supply to the unit is 
“ON” 

Not enough gas pressure. 

Ensure that the gas line has enough gas 
pressure.  Ensure that the gas tanks are not 

empty. 

Clogged or blocked burner injector 

orifice. 

Call your authorized service agent. 

Thermocouple connection to the 
gas valve is loose or too tight. 

Call your authorized service agent. 

Faulty thermocouple. 

Call your authorized service agent. 

Faulty gas valve. 

Call your authorized service agent. 

Only one burner will not 
turn “ON” 

Clogged or blocked burner injector 

orifice. 

Call your authorized service agent. 

Thermocouple connection to the 

gas valve is loose or too tight. 

Call your authorized service agent. 

Faulty thermocouple. 

Call your authorized service agent. 

Faulty gas valve. 

Call your authorized service agent. 

Two burners produce 
excessive carbon 

deposits 

Incorrect gas type supplied to unit. 

Ensure that the gas type supplied to the unit 
is correct based on the rating label.  Refer to 

the Gas Specification on Page 13. 

Only one burner in a unit 

produce excessive 
carbon deposits. 

Incorrect injector orifice installed. 

Ensure that a correct injector orifice is 

installed on the unit.  Refer to Gas 
Specification Table on Page 13 of this manual 

Flame comes out from 

the flue. 

Incorrect gas type supplied to unit. 

Ensure that the gas type supplied to the unit 
is correct based on the rating label.  Refer to 
the Gas Specification on Page 13. 

Incorrect injector orifice installed. 

Ensure that a correct injector orifice is 
installed on the unit.  Refer to Gas 

Specification Table on Page 13 of this manual 

Flashback  or  backfire  – 
when  the  flame  burns 

near  the  injector  and 
with a sound like a blow 
torch. 

Crack on the burner ceramic. 

Call your authorized service agent. 

    

 

Replacement Parts 

 

 

 

 

IMPORTANT: 

 

Only  genuine authorized replacement  parts should  be used  for the servicing and repair of  this  appliance. 
The instructions supplied with the parts should be followed when replacing components. 
For further information and servicing instructions, contact your nearest authorized service branch. 

 

When ordering replacement parts, please quote the  part  number  and the description listing  below.  If the 
part required is not listed below, request the part by description and quote model number and serial number 
which is shown on the rating plate. 
 

 

Содержание GE559-N

Страница 1: ...the vicinity of this or any other appliances Keep the area free and clear of combustible WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or...

Страница 2: ...arances Assembly Gas Connection Commissioning Operation 10 11 Operation Guide Description of Controls Lighting the Main Burner Main burner air supply Cleaning and Maintenance 12 Initial cleaning Daily...

Страница 3: ...IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOCATION THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER WARNING GREAT CARE MUST BE TAKEN BY THE OPERATOR TO US...

Страница 4: ...rating 1 0 kPa 2 75 kPa 2 75kPa Minimum inlet supply pressure 1 13 kPa 2 75 kPa 2 75 kPa Gas Connection BSP Male BSP Male BSP Male The burner operating pressure is to be measured at the gas control va...

Страница 5: ...4 Dimensions Dimensions for Gas Salamander Minimum clearance from grease filter minimum 600mm Refer AS NZS5601 Gas Installations Note Gas Salamander rack can carry a load of up to 15KG 33 lbf...

Страница 6: ...Components having adjustments protected by the manufacturer are only to be adjusted by an authorized service agent They are not to be adjusted by the installation person Step 1 Unpacking Step 2a Inst...

Страница 7: ...appliance in its approximate working position In accordance with AS NZS5601 Gas Installations 5 All air for burner combustion is supplied from underneath the unit The legs must always be fitted and n...

Страница 8: ...m 600mm 750mm We recommend allowing a clearance of 100 mm on either side of the appliance to allow access to the side panels for servicing purposes Using the wall mounting accessories provided with th...

Страница 9: ...them unscrewed by approximately 5 mm Refer to Fig 2 A 3 Fit the two adjusting screws bolts into the nut inserts at the bottom rear corners of the unit These should protrude approximately 30 mm from t...

Страница 10: ...fixed ex factory for the gas type 3 Correctly locate the appliance into its final operating position and using a spirit level adjust the legs so that the unit is level and at the correct height 4 Con...

Страница 11: ...y of a thermo electric system which will shut off the gas supply to that burner in the event that the burner goes out so that un burnt gas is not expelled 1 Select the burner required depress and turn...

Страница 12: ...designed and installed hood will act as the heart of the ventilating system for the room or area in which the unit is installed and will leave the unit independent of changing draft conditions All val...

Страница 13: ...ticles left on the surface will rust and further spoil the appearance of the finish NEVER USE A WIRE BRUSH STEEL SOURCING PADS EXCEPT STAINLESS SCRAPPER FILE OR OTHER STEEL TOOLS Surfaces which are ma...

Страница 14: ...he left side panel and right side panel 3 Replace the burner injectors See the parts list or Gas Specification Table below 4 Adjust the gas supply pressure and convert the gas regulator 5 Change ratin...

Страница 15: ...Page 13 Only one burner in a unit produce excessive carbon deposits Incorrect injector orifice installed Ensure that a correct injector orifice is installed on the unit Refer to Gas Specification Tabl...

Страница 16: ...15 Explosion drawing 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 20 21 23 22 25 26 27 19 24...

Страница 17: ...16 Explosion drawing Continued 29 30 31 32 33 34 35 36...

Страница 18: ...05 1029298 1 1 10 Upper inner1 01 15 1066418 1 1 11 Top cover 01 05 1029295 1 1 12 Feet1 02 12 1165053 2 2 13 Back hold plate 01 15 1066412 1 1 14 Back panel 01 15 1066415 1 1 15 Back inner plate 01...

Страница 19: ...Main pipe assembly 06 05 1472745 2 2 30 L connector 01 18 1067451 2 2 31 Main burner injector Orifice for Natural Gas 185 01 20 1068670 2 Main burner injector Orifice for LPG 109 01 20 1068671 2 32 I...

Страница 20: ...15 Badgally Road Campbelltown NSW 2560 Thor after sales service 1300 225 960 V1 Rev4 12 20...

Отзывы: