13
Adjustments
Warning: Adjustments and service work may only be performed by a qualified
technician who is experienced in, and knowledgeable with, the operation of
commercial cooking equipment. However, to assure your confidence, contact
your authorized service agency for reliable service, dependable advice and other
assistance, and of genuine factory parts.
In case of problems in operation at initial installation, check type of gas and manifold pressure and compare
information listed on the serial plate.
CONVERTING FROM ONE GAS TYPE TO ANOTHER
1.
Shut-off the main isolation valve and follow the lock-out/tag-out procedure.
2.
Remove the left side panel and right side panel.
3.
Replace the burner injectors. See the parts list or Gas Specification Table below.
4.
Adjust the gas supply pressure, and convert the gas regulator
.
5. Change rating label, warning label,
GAS SPECIFICATION TABLE
Natural Gas
Propane
ULPG
GE559-N
GE559-P
GE559-P
Single
burner
Heat
Input
16MJ/Hr
16 MJ/Hr
16 MJ/Hr
Heat Total
32 MJ/Hr
32 MJ/Hr
32 MJ/Hr
Burner Operating
1.0 kPa
2.75 kPa
2.75kPa
Supply Pressure
1.13 kPa
2.75 kPa
2.75 kPa
Gas Connection
¾” BSP Male
¾” BSP Male
¾” BSP Male
Burner Injector
Orifice#
#185
#109
Set-up of converter
Low
Flame
Size
Ø 0.65mm
Ø 0.65mm
Adjustment
Only if necessary
Only if necessary
CAUTION: Please replace the corresponding warning label that shows the gas
type operated when the qualified person will convert to another gas in order not
to cause death or injury or damage.