Adjustments
Technical Manual LDK 20(S) - Studio Camera
4-17
Video Miscellaneous Board
1. Place Video Miscellaneous Board on service extender.
VF sync. oscillator
2. Test sawtooth off.
3. Adjust VF sync. frequency.
Measure at:
Adjust with:
Required result:
MP2
ZL4
+2.5V DC level
Output amplitude
4. Test sawtooth on.
5. Adjust Y output amplitude.
Measure at:
Adjust with:
Required result:
PAL
NTSC
X17A-11
ZR92
+1400mV PAL
0%
10
90
100
0.2V
10µS
VA+1400mV
0%
10
90
100
0.2V
10µS
VA+1428mV
+1428mV NTSC
6. Adjust Y sync. output amplitude.
Measure at:
Adjust with:
Required result:
PAL
NTSC
X17A-11
ZR85
-600mV PAL
0%
10
90
100
0.2V
10µS
VA-600mV
0%
10
90
100
0.2V
10µS
VA-572mV
-572mV NTSC
R-Y / B-Y white balance
7. Test sawtooth off
8. Colour bar on.
9. Connect oscilloscope, via a vectorscope terminated with 75 Ohm, to the CVBS output of the camera and
adjust for a minimum unbalance in white.
Measure at:
Adjust with:
Required result:
Correct:
Incorrect:
CVBS out
ZR91
0.1
0.2
0.4
0.5
0.6
0.7
0.8
0.9
10
11
0.1
0.2
0.4
0.5
0.6
0.7
0.8
0.9
10
11
Содержание STUDIO CAMERA LDK 20(S)
Страница 1: ...LDK 20 S LDK 20 S LDK 20 S LDK 20 S LDK 20 S Studio Camera Technical Manual 3922 496 48591 St 00...
Страница 8: ...1 4 Technical Manual LDK 20 S Studio Camera Safety Instructions...
Страница 84: ...4 58 Technical Manual LDK 20 S Studio Camera Adjustments...
Страница 90: ...5 6 Technical Manual LDK 20 S Studio Camera Drawings...