Adjustments
Technical Manual LDK 20(S) - Studio Camera
4-37
Encoder Board PAL
Set-up
1. Switch off power. Place encoder board on service extender. Genlock camera with black burst signal. Switch
on power.
2. Connect oscilloscope via a vectorscope terminated with 75Ohm to the CVBS output of the camera.
3. Switch on colour bar.
Black balance
4. Turn chroma potentiometer R4 on encoder board fully clockwise (max. chroma).
5. Adjust the I and Q balance potentiometers for minimum unbalance in black.
Measure at:
Adjust with:
Required result:
CVBS out
ZR203
Smallest possible
ZR206
dot in centre of
vectorscope
6. Turn chroma potentiometer R4 on encoder board fully counterclockwise (zero chrominance).
CVBS amplitude
7. Adjust the CVBS gain potentiometer to obtain an output amplitude of 700mV for Y.
Measure at:
Adjust with:
Required result:
Correct:
CVBS out
R14
700mV
0%
10
90
100
0.1V
5µS
VA+700mV
R-Y amplitude
8. Turn R-Y gain potentiometer ZR205 fully clockwise.
9. Connect MP7 on the encoder board to ground.
10. Adjust with the chroma potentiometer until the colour vector dots correspond with the indication marks on the
V-axis of the graticule.
Measure at:
Adjust with:
Required result:
Correct:
CVBS out
R4
20
40
R
60
80
0.7
100
120
20
43
0.3
g
YL
MG
cy
b
B
yl
G
r
CY
mg
75
100
U
V
0
0
5
-5
%
VOLT
Содержание STUDIO CAMERA LDK 20(S)
Страница 1: ...LDK 20 S LDK 20 S LDK 20 S LDK 20 S LDK 20 S Studio Camera Technical Manual 3922 496 48591 St 00...
Страница 8: ...1 4 Technical Manual LDK 20 S Studio Camera Safety Instructions...
Страница 84: ...4 58 Technical Manual LDK 20 S Studio Camera Adjustments...
Страница 90: ...5 6 Technical Manual LDK 20 S Studio Camera Drawings...