Adjustments
Technical Manual LDK 20(S) - Studio Camera
4-3
Test Equipment
The following is a list of equipment required to carry out
the adjustment procedure:
•
Set of board extenders LDK 4830/21
•
Oscilloscope (with cursor measurement)
•
Spotlight 3200K
•
Gamma Test chart 4:3 / 16:9
•
Waveform monitor
•
Colour monitor
•
Multimeter
•
Master Control Panel LDK 4607 / LDK 4609
•
Operational Control Panel LDK 4624 / LDK 4628 /
LDK 4629
•
Audio Analyser
•
Base Station LDK 4053
Set-up Instructions
Before carrying out any adjustments the following steps
are recommended:
•
Install the camera on a tripod.
•
Attach the lens and the necessary cables.
•
Allow the camera to warm-up.
•
Operate the camera in stand-alone mode
•
Connect an MCP and OCP to the data connector on
the right connector panel of the camera.
•
When the camera is used in the stand-alone mode,
MCP and OCP always operate in camera select
position 1 (OCP camera select switch in position 1).
CAUTION:
Do not attempt to improve camera performance
by adjusting individual potentiometers, jumpers or switches
as this may lead to complete misalignment of the camera.
CAUTION:
Do not realign individual potentiometers, jumpers or switches
not mentioned in this chapter or earlier in this manual.
These adjustment points are for factory use only.
CAUTION:
Switch off the power supply to the camera
before removing or replacing printed circuit boards.
Содержание STUDIO CAMERA LDK 20(S)
Страница 1: ...LDK 20 S LDK 20 S LDK 20 S LDK 20 S LDK 20 S Studio Camera Technical Manual 3922 496 48591 St 00...
Страница 8: ...1 4 Technical Manual LDK 20 S Studio Camera Safety Instructions...
Страница 84: ...4 58 Technical Manual LDK 20 S Studio Camera Adjustments...
Страница 90: ...5 6 Technical Manual LDK 20 S Studio Camera Drawings...