![Thinklogical HDX576 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/thinklogical/hdx576/hdx576_product-manual_1107281018.webp)
Revision A December 2011
10
The HDX Routers Critical Hardware Alarms are as follows:
The
HDX
576 Router Critical Hardware Alarms:
1
2
3
4
5
6
7
8
9
10
POWER SUPPLY 1 (LEFT):
POWER SUPPLY 2 (RIGHT):
FANS:
TEMPERATURE WARNING:
TEMPERATURE SHUTDOWN:
CPU:
INPUT/OUTPUT CARDS:
ANY OF THE ABOVE
COMMON
GROUND
The
HDX
80 Router Critical Hardware Alarms:
Fan failure, temperature spikes, DC voltage and/or current out of range
,
AC power input interruption
and
module removed
Fan failure, temperature spikes, DC voltage and/or current out of range
,
AC power input interruption
and
module removed
Individual fan monitoring
Chassis over temperature, multiple sensors
Chassis over temperature causing shutdown
Card failure (Only with a redundant card)
SFP+ failure, laser output fault
1
2
3
4
5
6
7
8
9
10
11
12
POWER SUPPLY 1 (LEFT):
POWER SUPPLY 2:
POWER SUPPLY 3:
POWER SUPPLY 4 (RIGHT):
FANS:
TEMPERATURE WARNING:
TEMPERATURE SHUTDOWN:
CPU:
INPUT/OUTPUT CARDS:
ANY OF THE ABOVE
COMMON
GROUND
Fan failure, temperature spikes, DC voltage and/or current out of range
,
AC power input interruption
or
module removed
Fan failure, temperature spikes, DC voltage and/or current out of range
,
AC power input interruption
or
module removed
Individual fan monitoring
Chassis over temperature, multiple sensors
Chassis over temperature causing shutdown
Card failure (Only with a redundant card)
SFP+ failure, laser output fault
Fan failure, temperature spikes, DC voltage and/or current out of range
,
AC power input interruption
or
module removed
Fan failure, temperature spikes, DC voltage and/or current out of range
,
AC power input interruption
or
module removed
Figure 4: Alarm Descriptions and Drawing for the HDX80 and HDX576
Controller Card
The hot-swappable Controller Card connects the Router to an external Linux or Windows CPU.
The serial port can also be used for 3rd party controller integration (such as Crestron, AMX or
home-spun interfaces). Also, the
X4 Configurator Software (Appendix C) can be used to control the
Router via the LAN port.
If the HDX Router is to be controlled via ethernet, it will require a static IP address. This value
can be set via the DIP switch to the values listed below. The factory default setting will be
192.168.13.15.
Содержание HDX576
Страница 2: ......
Страница 8: ......
Страница 15: ...Revision A December 2011 7 Figure 2 HDX576 Router Rear View...
Страница 43: ...Revision A December 2011 35 Appendix B Quick Start Guides...
Страница 44: ...Revision A December 2011 36...
Страница 45: ...Revision A December 2011 37 Appendix C SD Flash Card Replacement...
Страница 46: ...Revision A December 2011 38...