ModuLam 130 Operators Manual
page 6
C. Temperature Control
1. The se buttons are used to increase and decrease the temperature set-point. As
might be expected, the UP arrow increases the temperature, the DOWN (DN)
arrow lowers it. After changing the temperature, allow at least 10 minutes for the
laminator to reach equilibrium.
2. The range that the temperature can be adjusted is from room temperature (RT) to
160°C in increments of 1°C. If the actual temperature exceeds 160°C (overshoot),
a warning beep will sound and the heat will automatically be reduced.
•
Press the MEASURE (MEAS) button to display the current temperature of the
fusion rollers. The temperature will be displayed for 3 seconds before the
displays reverts to the set-point.
D. Motor / Speed Control
The speed of the rollers can be adjusted in 6 increments using these buttons (1
being the slowest, 6 the fastest). It is a good idea to record both the temperature
and the motor speed for each type of film that you use. The accuracy of the
Think & Tinker lamination controller allows you to return to the same operating
parameters with the touch of a couple of buttons.
This momentary switch is used to turn off the drive motor. The motor will restart
as soon as the button is released. When the rollers are at operating temperature, it
is not a good idea to keep this button depressed for long periods of time as
damage to the silicone coating may result.
This momentary switch is used to reverse the rotation of the rollers. It is used to
remove jammed substrates as well as neck ties that have been dragged into the
laminator.