TUNDISH

The tundish supplied must be fitted visible to the occupier. The

discharge pipe must be 22mm copper pipe. Regulations do not

permit more than 3 x 90-degree bends between the unit

and the outflow. Between the temperature & pressure relief valve

and the first 90-degree bend there must be a fall of at least

300mm. The fall of the pipework must be continuous and the pipe

should terminate in the gully or be bent backwards onto an

outside wall, in a place where discharge cannot be injurious to

persons.

If you need to site the unit In the middle of the house then

your discharge pipe to the tundish can be as far away as 9m, which

in most cases is enough to run the final discharge point. After 9m,

increase the pipe size to a greater diameter than 22mm and

accordingly for subsequent 9m lengths, see table 1 on page 10.

COMMISSIONING THE UNIT

Switch on electricity to the immersion heater(s) (Direct system) or

switch on the boiler (Indirect system). Refer to the boiler

manufacturers instructions on commissioning.

Bring the unit to its maximum temperature setting of approx. 60

degrees Celsius. You should, on operating the water taps, have a

good flow of hot and cold water assuming adequate water is

supplied to the unit.

Check the water does not discharge via the tundish pipework

during heating.

Recheck all fittings/joints for possible leaks.

On completion of the installation, before turning on the mains

water supply ensure that all residual materials are removed by

means of flushing the system with a "fernox" type cleaner or

equivalent.

EXTERNAL EXPANSION TANK

This smaller tank is connected to the cold-water inlet side of the

vessel. Mount the tank according to separate manufacturers

instructions provided with the External Expansion Tank.

See fig 1 page 5.

SCALE

In hard water areas lower water temperatures can result in less

scale being deposited.

If water softener is used it should be capable of flows of approx. 50

lt/min, this will maintain maximum performance of the unvented

unit.

If no descaler or softener is used then the heating element(s) will

need descaling periodically for maximum efficiency.

DRAINING

Switch off electrical power to immersion heaters and/or shut down

the boiler. Close the stopcock valve to isolate the unit.

Attach hosepipe to the drain cock having sufficient length to take

water to a suitable discharge point.

Open drain cock

Open hot water tap nearest to the unit.

If water fails to drain from unit, vent the system by

opening the temperature pressure relief valve.

DISCHARGE PIPEWORK 

It is a requirement of Building Regulations that any discharge from

an unvented system is conveyed to where it is visible, but will not

cause danger to persons in or about the building. The tundish and

discharge pipes should be fitted in accordance with the

requirements and guidance notes of Building Regulations. Building

Regulation G3 Requirements and guidance section 3.9 reproduced

in the following sections.

Information Sheet No. 33 available from the British Board of

Agreement gives further advice on discharge pipe installation. For

discharge pipe arrangements not covered by G3 Guidance or BBA

Info Sheet No. 33 advice should be sought from either your local

Building Control Officer

SCHEMATIC DISCHARGE
PIPE ARRANGEMENT

Fig.6

Содержание unvented water heater

Страница 1: ...unvented water heater installation manual 3bar kit version...

Страница 2: ...LAND BUILDING REGULATION P5 AFTER INSTALLATION THE BENCHMARK LOG BOOK MUST BE COMPLETED AND LEFT ALONG WITH THESE INSTRUCTIONS WITH THE HOUSEHOLDER FOR FUTURE REFERENCE INSTALLATION INSTRUCTION MANUAL...

Страница 3: ...jam or leak no noise from tank filling All your water hot and cold is direct from the mains Site the unvented water heater wherever convenient Your vessel fills your bath in minutes and will run two a...

Страница 4: ...05 litres and 80 litre DH direct model 2 Elements on DH direct models from 130 up to 305 litres Additional elements from 215 to 305 litres are available on request Cold water control valve comprising...

Страница 5: ...roperty with short lengths max 1 metre runs of 15mm going to baths showers and basin taps Smaller bore pipe can be used to suit taps SECONDARY CIRCULATION This is particularly easy to fit on unvented...

Страница 6: ...6 SECONDARY CIRCULATION CONNECTION DIAGRAM Fig 3 2 2 PORT S PLAN VALVE SYSTEM GUIDANCE LAYOUT ONLY Fig 4...

Страница 7: ...er thermostat fails WARNING Ensure that the immersion heater thermostat is set at 60 degrees Celsius FITTING THE THERMAL CUT OUT PRIMARY CONNECTIONS The motorised valve supplied and the thermal cut ou...

Страница 8: ...equivalent EXTERNAL EXPANSION TANK This smaller tank is connected to the cold water inlet side of the vessel Mount the tank according to separate manufacturers instructions provided with the External...

Страница 9: ...ully ii downward discharges at low level i e up to 100mm above the external surfaces such as car parks hard standings grassed areas etc are acceptable providing that where children may play or otherwi...

Страница 10: ...perate change the complete heating element assembly Important In the event of an over heat situation reset all thermal cutouts If hot water discharges from Tundish WARNING Do not turn the mains water...

Страница 11: ...egular service stamp by a qualified unvented installer Exclusions The guarantee does not cover The effects of large scale build up Any labour charges associated with replacing the unit or outs parts A...

Страница 12: ......

Отзывы: