Label Calibration
BA_TT5-L_GB_V(0).DOCX
page 30
6.7 Label Calibration Button
A hardware button to make a Label Calibration while printer encountering ‘’Media Error’’ during the cases when
first-time printer start up or change label to another type, such as change using gap label to continuous or black
mark labels.
Press Calibration button for 1 ~ 2 seconds, it will make an auto-sensing to
calibrate the label’s parameters.
NOTE: *Press Calibration button is equivalent to the auto-
sensing command ‘’~S,SENSOR’’ that will cancel on-
printing-job and make the Label Calibration immediately.
**It can also be launched through following Menu: Main => Printer Control => Calibration
Press and hold about
1 ~ 2 seconds
CALIBRATION BUTTON