background image

RENEWABLE  HEATING & COOLING TECHNOLOGY

Electrical connection

The Electrical supply must correspond to that indicated on the appliance.
All supply cables have to be sized according to the appliance power and installation 
requirements.
Please refer to below table:

Heat Pump

Cable Size

3x

mm

2

3x .0mm

2

x

mm

2

LCSPI-170

LCSPI-210

LCSPI-250

LCSPI-300

The above are an indication only.Please refer to a qualified Electrician if in doubt.
Use the cable glands and grommets provided inside the heat pump to secure and 
route the supply cables.

Trial Running

After connecting the unit to the pool system, ensureyour installation is complete, with 
a suitable by-pass and electrical connections by a qualified engineer.

Be sure that:
1)  Appliance is horizontal and on a firm base.
2)  Water system has no leaks.
3)  Electrical Installation is compliant with all local regulations and standards.
4)  The installation requirements described previously have been strictly adhered to.

!

ATTENTION: THE HEAT PUMP ONLY OPERATES WHEN WATER FLOW IS PRESENT.

You can start up the heat pump following the procedure below:
-Open by-pass valves
-Start pool system pump
-Turn on pool heat pump
-Set controller

Page 8

5 2.5

x

mm

2

5 2.5

x

mm

2

5 2.5

x

mm

2

5 2.5

4

2.5

LCSPI-120/150

Содержание LCSPI-120

Страница 1: ...RENEWABLE HEATING COOLING TECHNOLOGY Swimming Pool Heat Pump Enjoy longer swimming seasons with less cost Operation Installation Manual...

Страница 2: ...ONTENTS OVERVIEW OF THE UNIT INSTALLATION Installation guidelines Locating your Unit Water connection Electrical connection Trial running OPERATING THE UNIT Features and functions User interface Butto...

Страница 3: ...be used with all types of water treatment including chlorine iodine bromine and salt water Multiple functions Cooling and heating functions available Auto operation Auto restart Auto defrost Auto time...

Страница 4: ...pply If there is no suitable earthed supply available have one installed by a qualified electrician Do not move repair the unit yourself Before carrying out any maintenance service or repair work the...

Страница 5: ...OGY CONTENTS Before starting the installation please make sure that all items are found inside the box The Unit Box Item Image Qty Swimming pool heat pump 1 Operation and Installation Manual 1 Accesso...

Страница 6: ...RENEWABLE HEATING COOLING TECHNOLOGY OVERVIEW OF THE UNIT Page 5 LCSPI 120 150 170...

Страница 7: ...Page 6 RENEWABLE HEATING COOLING TECHNOLOGY EXPLODED VIEW...

Страница 8: ...ed to a solid wall Try to avoid placing the unit under a tree or exposed to extreme conditions Water connection The heat pump is connected to a filtration circuit with a by pass It is imperative that...

Страница 9: ...e supply cables Trial Running After connecting the unit to the pool system ensureyour installation is complete with a suitable by pass and electrical connections by a qualified engineer Be sure that 1...

Страница 10: ...THE BUTTONS OF THE DIGITAL CONTROLLER WITH A HARD POINTED OBJECT THIS MAY DAMAGE THE DIGITAL CONTROLLER NEVER INSPECT OR SERVICE THE DIGITAL CONTROLLER YOURSELF REFER TO A QUALIFIED SERVICE ENGINEER B...

Страница 11: ...tory parameter query interface factory parameter query password 0814 manufacturer setting password 8563 On factory parameter query interface screen press to enter into parameter setting interface pres...

Страница 12: ...wer off On Timer setting interface screen press to confirm current Timer settings and back to main operation interface Settings way for other groups of Timers is same as Timer 1 Timer 1 2 are for unit...

Страница 13: ...A10 Reserved E1 E6 Error code display Parameter settings User parameters can be adjusted by users Code Parameter Name Range Default L2 Outlet water temp variation for compressor start 2 25 5 L3 Outle...

Страница 14: ...No action needed Er 05 High pressure protection 1 Inadequate flow rate 2 Uncompressed gas in refrigerant system 3 Overcharge with refrigerant 4 Water temp setting too high 5 Poor connection of pressur...

Страница 15: ...ed using compressed air or by flushing with clean water It may be necessary to remove the unit cover and air inlet grid first Attention Before opening the unit ensure that all electrical supplies are...

Страница 16: ...sales service technician Work on the heat pump may only be carried out by authorized and qualified after sales service technicians ENVIRONMENTAL INFORMATION This equipment contains fluorinated greenh...

Страница 17: ...be treated at a specialized treatment facility for re use recycling and recovery By ensuring that this product is disposed of correctly you will help to prevent potential negative consequences for th...

Страница 18: ...Page 17 RENEWABLE HEATING COOLING TECHNOLOGY WIRING DIAGRAM Please refer to the wiring diagram on the electric box Model LSCPI 120 150 170...

Страница 19: ...Page 18 RENEWABLE HEATING COOLING TECHNOLOGY Model LCSPI 210 250 300...

Страница 20: ...Page 19 RENEWABLE HEATING COOLING TECHNOLOGY TECHNICAL SPECIFICATIONS...

Отзывы: