Service & Maintenance 

 

Always disconnect and isolate the mains electricity supply before installing, 
maintaining or repairing this equipment.  Note: All maintenance/repairs should 
only be carried out by a competent electrician or Thermoscreens appointed 
technician.  

 

Once the mains supply is isolated, remove end caps from the air curtain (if fitted).  
Remove each air intake grille by unfastening two screws on each grille - M4 x 10mm 
Pozi No.2 screws accessed via the larger hole at the bottom of each grille. 

 

To ensure the air curtain operates at full efficiency the inlet/outlet grilles, fan impellers, 
housings and motors must be kept free of dust and debris.  Build up of dust on the fan 
impellers can cause vibration, noise and excessive wear on the motor bearings. 

 

Frequency of cleaning will depend on the environment, but we would recommend that 
the unit be cleaned a minimum of every 3 months (failure to adequately maintain the 
unit and provide a suitable cleaning schedule will result in performance degradation 
and reduce the life expectancy of the air-curtain). 

 

Vacuum and clean the build-up of dirt and debris within the air-curtain 

(please note 

that the motor(s) are permanently lubricated and require no additional lubrication). 
If filters are fitted, ensure these are regularly inspected and cleaned or replaced.  All 
dirty or blocked filters should be immediately replaced. 

 

Once the air curtain has been cleaned check all electrical connections within the unit 
ensuring terminals are tight and that crimped connections have not become loose. 
Refit inlet grilles and end caps.  Reconnect the electrical supply and fully function test 
the air-curtain to ensure correct operation (See Commissioning). 

 

If the outer casing requires cleaning this should be done using a warm soft cloth. 
Do not use solvents or abrasive materials. 

 

 

 Warranty 

 

If any problems are encountered, please contact your installer/supplier.  Failing this 
please contact the Thermoscreens warranty department.  All units are covered by a two 
year warranty period. 

 

Care has been taken in compiling these instructions to ensure they are correct, although 
Thermoscreens disclaims all liability for damage resulting from any inaccuracies and/or 
deficiencies in this documentation.  Thermoscreens retain the right to change the 
specifications stated in these instructions. 

 

Thermoscreens Ltd  

 

 

 

 

 

St. Mary’s Road  Nuneaton 
Warwickshire  England  
CV11 5AU 

   

 

 

 

 

 

Email: 

[email protected]

 

Tel:  + 44 (0) 24 7638 4646 
Fax: + 44 (0) 24 7638 8578 

www.thermoscreens.com

 

Содержание C series

Страница 1: ...ION MAINTENANCE INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION Thermoscreens Ltd St Mary s Road Nuneaton Warwickshire England CV11 5AU Email sales thermoscreens com Tel 44 0 24 7638 4646 Fax 44 0 24 7638 8578 www thermoscreens com ...

Страница 2: ...l Brackets Fixing Bolts additional bracket and bolts supplied for C1500 C2000 models Note Optional filters are available on Water and Ambient models only and are packed separately If anything is missing or damaged please contact your place of purchase immediately For your records Date of Purchase Place of Purchase Serial Number For warranty purposes proof of purchase is necessary so please keep a ...

Страница 3: ...t see table 1 Step 1 Refer to Figure 1 for mounting details and drill the wall accordingly Step 2 Screw in the top bolts leaving a small gap between the head and the wall lower the unit onto the bolts via key hole slots in the top of the wall brackets and then screw in the bottom bolts Step 3 Ensure all fixing bolts are tightened to stop the unit being lifted off the wall Ceiling Suspension 6mm th...

Страница 4: ...r 25mm gland Electrical supply inlets C1500 C mm N A E mm F mm D mm N A 161 710 B mm A mm C1000 1137 908 275 Rp 1 2 1 2in BSP female LPHW connections 964 704 161 874 1748 604 170 1208 21 120 1928 2200 C2000 1408 1669 M6 inserts C B A C 198 100 min 220 E D E 33 F 75 Figure 1 ...

Страница 5: ...lectrical supply the unit requires a neutral connection 3N Cable glands used for the Electrical Input must be rated IP21 or higher Table 1 Air Curtain Electrical Supply V ph Hz Rated Power Input kW Current per phase A Heat Output kW Weight kg C1000A 230 1 50 0 15 0 7 N A 15 C1500A 230 1 50 0 20 0 9 N A 21 C2000A 230 1 50 0 25 1 1 N A 31 C1000W 230 1 50 0 15 0 7 6 0 18 C1500W 230 1 50 0 20 0 9 9 0 ...

Страница 6: ...s isolation valves are fitted in the flow and return pipework When fitting the 3 port valve ensure that the pipe connections are fitted as detailed below and are in accordance with the manufacturers leaflet supplied with the valve Air Curtain Water Flow Rate l s 82 72 C Coil Water Pressure Drop kPa C1000W 0 14 2 77 C1500W 0 21 6 74 C2000W 0 29 13 40 Ambient Models Ambient units are supplied with a...

Страница 7: ...x M3 5 mounting screws not provided With the cable RJ plug locking clip lying nearest to controller PCB connect the RJ plug to the RJ socket on the board Note For controller DIP switch options refer to Ecopower Plus Remote Control Operation and DIP Switch Settings Refit the controller front case to the back case The air curtain end of the control cable should be connected to one RJ socket fitted e...

Страница 8: ...ins where some units can blow cold air whilst others can blow warm air because they currently all refer to their own air sensor for control of the heat output of each air curtain The master air curtain need not be the one that the wall control is plugged into This dip switch setting must also be used for Global Switching Master Slave via the INHIBIT terminal see next page As supplied the default s...

Страница 9: ...need connect the remote contact to only one of them to turn all units on and off in the master slave system For global switching to work on the slave units need to set DIP3 Option see previous page on the unit that the remote contact is wired to and have previously turned the unit on with the wall switch As supplied a wire link will be fitted to the terminal block on every unit For summer settings...

Страница 10: ...4001160 6 UK Page 10 of 16 ...

Страница 11: ...4001160 6 UK Page 11 of 16 ...

Страница 12: ...4001160 6 UK Page 12 of 16 ...

Страница 13: ...o dissipate excess heat DIP Switch Settings At the back of the Ecopower Plus remote control PCB there are four DIP switches see above that provide the following optional features DIP1 Restart on Power Up If electrical supply to the air curtain is interrupted upon restoring electrical supply the customer s settings on the remote control will be retained The default is with this feature ON DIP2 Stop...

Страница 14: ...or replacement Fault Conditions In the event of a fault the thermal cut out s Note If the mains supply is isolated during operation then the thermal cut outs may operate or internal fuses may operate The thermal cut out s are located on the top face of the unit directly above the element banks one on the 1 1 5m and two on the 2m model For Ecopower units two internal electrical fuses are located on...

Страница 15: ...act Installer Service Agent to investigate why thermal cut out s have operated Service Agent to reset thermal cut out s Contact Installer Yes No Yes Yes No No No Yes Yes No No Is Electrical Power switched on Are the fans operating correctly Is the unit discharging warm air Check if thermal cut out s have tripped Electric Heated only Do the LED s light up on the remote control Is the remote control...

Страница 16: ...in please note that the motor s are permanently lubricated and require no additional lubrication If filters are fitted ensure these are regularly inspected and cleaned or replaced All dirty or blocked filters should be immediately replaced Once the air curtain has been cleaned check all electrical connections within the unit ensuring terminals are tight and that crimped connections have not become...

Отзывы: