Page 9
Installation, use and maintenance guide
3 – GENERAL DESCRIPTION
3.1 OPERATING TECHNOLOGY
Your appliance has been built to fully satisfy all your heating and practical requirements. Top-grade components and functions
managed with microprocessor technology guarantee high reliability and optimal performance.
3.2 THE PELLET
The appliance is fuelled by pellets, that is, cylinders of compressed sawdust; this allows you to fully enjoy the heat of the flame
without having to manually stoke the combustion.
The pellets have a 6 mm diameter and a maximum length of 15 mm. They have a maximum moisture content of 8%; thermal value
4000/4500 Kcal/Kg and density of 620-630 Kg/m³, less than 0.7% ash content.
It is strictly forbidden to use any pellet type other than that specified above. (UNI EN 14961-2 A1 and A2). The use of fuel
that does not comply with the above specifications not only immediately invalidates the warranty for the appliance but can
also create dangerous situations. Do not use the appliance as an incinerator, at the risk of voiding the warranty.
IMPORTANT: shut off the appliance before loading the pellets.
3.3 THE FEEDBOX
The feedbox is situated in the top part of the appliance. The load
capacity specified in the technical data can vary according to the
specific weight of the pellets.
Take special care when loading the tank of the screw feeder at
its base. Take care when topping up with fuel as the loading
area can get very hot.
Only pellets that comply with the specifications listed above
must be fed into the tank;
Never insert foreign objects into the tank. To access the feedbox
firstly remove the tank cover as illustrated in Figure 1.
Attention: when loading the pellets into the tank take care not to
drop any in the inner parts of the appliance, as this could cause
live flames inside the appliance. The manufacturer recommends
emptying the tank and vacuuming the screw feeder zone once a
month and during the summer period. The appliance is
designed to run on pellet fuel. Use of other combustible
materials in the tank and/or combustion chamber is strictly
prohibited.
4 - INSTALLATION
4.1 APPLIANCE LOCATION
Follow the general guidelines set out in paragraph 1.1 to the letter. Keep in mind that the flooring of the room in which
the appliance is to be installed must withstand the combined weight of the appliance and the pellets contained in the
tank.
CAUTION: The appliance must be installed in a room with adequate ventilation. The appliance must be positioned at
a minimum safe distance from walls and furnishings. If inflammable items are positioned near the appliance
(matchboarding, furniture, curtains, wall hangings, sofas, etc...), this gap must be increased considerably. The
recommended minimum distances are illustrated in Figure 1. If the flooring is made of wood or any other combustible
material, it is recommended to install a fireproof floor protector plate between the appliance and the floor. Installation
in the vicinity of heat-sensitive materials is only permitted if suitable insulating and fireproof protection is placed
between the object and the appliance (ref. Uni 10683). Failure to observe this instruction will immediately invalidate
the warranty.
The installer must issue a certificate of conformity for the installation which includes the design plans and the
following documents:
a) Report containing the type of materials utilised.
b) Project as defined in Article 5 of Ministerial Decree n° 37 22 January 2008.
c) Drawing of the finished installation.
d) References to existing partial or previous declarations of conformity (e.g. electrical wiring).
e) Copy of the certificate of recognition of the professional technical qualifications.
Figura 1
Содержание SlimQuadro 11
Страница 2: ...Page 2 Installation use and maintenance guide ...
Страница 5: ...Page 5 use and maintenance guide EC DECLARATION OF CONFORMITY ...
Страница 26: ...Page 25 and maintenance guide ...
Страница 42: ...Page 41 and maintenance guide NOTES ...
Страница 43: ...Page 42 lation use and maintenance guide NOTES ...