Tutte le tubazioni devono
essere termicamente isolate.
LEGENDA
KEY
Tutte le tubazioni devono essere termicamente isolate
All the pipes must be thermally insulated
Comignolo e canna fumaria secondo norma UNI 10683
Chimney cap and flue outlet according to uni 10683 standard
Interno
Internal
Esterno
External
Ispezione
Inspection
Lastra di copertura
Cover slab
Lamiera di acciaio a tenuta stagna
Watertight steel sheet
2 metri MAX (pendenza 3% - 5%)
2 metres MAX. (slope 3-5%)
Altezza superiore a 5 metri
Height more than 5 m.
9.3.3 CONTROLS PRIOR TO INSTALLING THE
APPLIANCE
The user must possess a certificate of conformance for the
flue outlet (Ministerial Decree 22 January 2008, no. 37).
The flue outlet must be built in compliance with UNI 10683.
The smoke exhaust shown in the following figures is the
best solution to ensure the discharge of smoke even when
the fan is not operational, such as for example if there is
an electrical power failure. Failure to observe these
requirements could result in stagnation of the gases in the
firebox and could explode when discharged to the
environment. The figures illustrate the best solution for
discharging the smoke out through the roof or into the flue
outlet. If you prefer to exhaust the smoke from the roof
insert a union tee with inspection cap, connecting brackets
suitable for the height of the flue outlet, flashing that
crosses the roof and chimney cap to protect against bad
weather conditions.
If you decide to use the classic masonry exhaust provide a
T-union with inspection
cap and suitable supporting brackets. If the flue outlet is
too big it is necessary to insert a stainless steel or
porcelain-coated steel tube with a diameter not exceeding
150mm. Seal area where the inlet and outlet part of the
smoke exhaust meets the wall. It is strictly forbidden to
apply mesh to the end of the outlet tube, as it could cause
the appliance to malfunction. If the smoke tube is installed in a fixed position it is advisable to provide inspection openings for clean-
out purposes especially in the horizontal sections. See the diagram. These openings are essential to allow for the removal of ash
and unburned products which tend to accumulate along the discharge path. The appliance functions with the combustion chamber
in a vacuum, while the discharge of smoke to the flue outlet has a slight pressure, consequently it is imperative to ensure that the
discharge system is hermetically sealed. The smoke discharge tube must be made from suitable materials such as for example:
porcelain-coated steel tubes, and the various fittings sealed with red silicone (resistant to 350°C). The outer casing of the tube must
be made with insulating material (mineral wool, ceramic fibre) or use pre-insulated tubing.
THE FLUE OUTLET MUST BE USED ONLY FOR THE APPLIANCE.
ISPEZIONE
C
O
M
IG
N
O
L
O
E
C
A
N
N
A
F
U
M
A
R
IA
S
E
C
O
N
D
O
N
O
R
M
A
U
N
I
1
0
6
8
3
INTERNO
ESTERNO
T
u
tt
e
l
e
t
u
b
a
z
io
n
i
d
e
v
o
n
o
e
s
s
e
re
t
e
rm
ic
a
m
e
n
te
i
s
o
la
te
.
T
u
tt
e
l
e
t
u
b
a
z
io
n
i
d
e
v
o
n
o
e
s
s
e
re
t
e
rm
ic
a
m
e
n
te
i
s
o
la
te
.
ISPEZIONE
COMIGNOLO E
CANNA FUMARIA
SECONDO NORMA
UNI 10683
T
u
tt
e
l
e
t
u
b
a
z
io
n
i
d
e
v
o
n
o
e
s
s
e
re
t
e
rm
ic
a
m
e
n
te
i
s
o
la
te
.
LASTRA DI
COPERTURA
LAMIERA DI ACCIAIO
A TENUTA STAGNA
Содержание SlimQuadro 11
Страница 2: ...Page 2 Installation use and maintenance guide ...
Страница 5: ...Page 5 use and maintenance guide EC DECLARATION OF CONFORMITY ...
Страница 26: ...Page 25 and maintenance guide ...
Страница 42: ...Page 41 and maintenance guide NOTES ...
Страница 43: ...Page 42 lation use and maintenance guide NOTES ...