THERM 90 KD.A

!

The mentioned ad-in regulators are not (with the exception of special offers) included in the delivery of the boiler!

Description of the activity of the boiler in the mentioned regime:

The working phase of the boiler starts by switching on the room thermostat (the thermostat evaluated  low temperature 

compared with requested) at the moment when the regime control knob is in the winter regime position. The three-way 

valve relay is disconnected (for boilers with water storage heating); the of circulating pump is activated, as well as the ignition 

system and ventilator. Ignition of the boiler is for the adjusted starting output. It remains for 2 seconds after activation of the 

boiler. The output is then decreased to the minimum with a slow linear start (about 50 s) to the modulation point stated by 

service for setting the maximum heating output. The regulation of output of the boiler in this phase is by PID (proportional/

integral/derivative) with keeping the temperature set by the wheel on the control panel (within the range 30 – 80 °C). During 

the whole time of heating, the regulation limit of the output temperature is checked. When heating the system with lower 

input power than the minimum output of the machine, there is an increase of the output temperature of heating water by 

3 °C above the adjusted temperature (for 30 seconds from ignition, this value is increased to 10 °C). In this phase the boiler 

interrupts the burning while still running the circulating pump and activates the restriction of reignition (service setting within 

the range 0 – 10 min.). In this manner the boiler becomes a highly adaptable source of heat due to the high variability of the 

consequently regulated heating sets (e.g. use of zone regulation, thermostatic valves, etc.).
After disconnection of the spatial thermostat or after switching the selection unit into the “WINTER“ mode, the burning of 

the burners is stopped and the pump is ON for the set time (service setting within the range 0 – 10 min.). This function is 

used for taking the heat from the condensing body and for  improving the allocation of temperatures of bodies when using 

thermostats with PI linkage with short working cycles.

In the case of the installation of the room thermostat eventually. and controller in the reference room, a minimum 

of one radiator must be left without a thermostat head. To increase thermal comfort, we recommend not to 

mount thermostatic heads on radiators in the reference room at all.

 

2.3.3  Operation of the boiler using built-in equithermal regulation

This regime is accessible in the boiler in the standard variant but is not activated. The activation and the primary setting of 

the regulation is performed at the request of the client by an authorized service technician.
During equithermal regulation the boiler changes the temperature of the heating water automatically according to the 

changes in the outside temperature.
This manner of regulation can only be used with the connected outside temperature sensor. The outside sensor is located on 

the coldest wall of the object (north or north-west) approximately 3 m above the ground. The sensor must not be influenced 

by any other thermal influence such as open windows, sunlight, ventilation shafts, etc.

Description of the activity of the boiler in this regime:

 The working phases of the boiler are identical with the previous regime with the difference that the temperature for the 

heating system is automatically set according to the outside temperature (ascertained by the sensor). The calculation of the 

requested temperature of the heating system is the function of the ambient temperature and the function of the “K“ factor 

(declination of equithermal curve), which is set by the service technician with respect to the locality and nature of the heating 

system. Using the heating water knob on the control panel, the user sets the requested thermal comfort (correction of the 

shift of equithermal curve within the range ± 15 °C of the heating water). The equithermal curve is modified for standard 

heating systems with radiators.
In the case of failure of the ambient temperature sensor, this status is signalled by E07 failure and the boiler continues in 

operation with the temperature of the heating system according to the setting in the previous regime (without equithermal 

regulation).

Adjustment procedure:

When setting the equithermal regulation, it is necessary to distinguish the declination and the shift of the equithermal curve. By 

setting of 

the declination 

 the following rule applies : in the case of poor thermal-insulating properties of the object, change 

the parameters of the declination of the curve 

in the direction of the higher values (the curve 

is moved upward); in the case of good thermal 

insulation, the parameter can be decreased (the 

curve is moved downward).

The declination of the curve is set by the 

authorized technician in the service menu of 

the automatic control system of the boiler!

Содержание THERM 90 KD.A

Страница 1: ...Manual for installation operation and maintenance of boiler Hanging gas condensing boiler THERM 90 KD A...

Страница 2: ...THERM 90 KD A Manual for installation service and maintenance of boiler...

Страница 3: ...Complete character of the delivery 19 3 3 Location of the boiler 20 3 4 Suspending the boiler 20 3 5 Connecting the boiler to the hot water system 21 3 5 1 Dimensions and connection 21 3 5 2 Graphs of...

Страница 4: ...res to maintain the minimum pressure of the water in the heating system of 0 8 bar measured in cold state With regard to their power and use variability the THERM 90 KD A boilers are not fitted with e...

Страница 5: ...al to the volume of air through the mixer delivered with the ventilator Therefore it can be stated that the output on the boiler depends on the volume of the air flow for combustion As a result the re...

Страница 6: ...gases disconnect the boiler ensure ventilation of the room windows door call service the boiler must not be used until after the service inspection In the case of a consumer appliance fire close the g...

Страница 7: ...Temperature of glue gases in overheated condition C 82 Lower flue gas temperature at minimum thermal power C 25 Weight flow of burnt gases g s 1 10 2 42 8 Weight flow of flue gases at minimum thermal...

Страница 8: ...et of boiler THERM 90 KD A 1 Condensing chamber 2 Ventilator 3 Heating temperature probe 4 Mixer 5 Emergency thermostat 6 Circulation pump 7 Gas valve 8 Safety valve 9 Control panel 10 Pressure switch...

Страница 9: ...ummer regime only heating of DHW is ON the heating is OFF Winter regime heating and heating of DHW is ON Unblocking the failure status of the boiler Service mode the function sweeper the output of the...

Страница 10: ...er the termination of the setting the indication of the set temperature remains for about 5 seconds The following permanent display of the numeric value and the symbol the real temperature of the resp...

Страница 11: ...rface of the cascade is active Description of symbols shown on the display 2 1 3 Information menu Buttons and are used for entrance and bi directional browsing in the information menu in the following...

Страница 12: ...is attached to the product The procedure for the first ignition of the boiler is as follows set the rotary button of the input temperature of the heating water of the boiler to the maximum insert the...

Страница 13: ...least a simple room thermostat The room temperature is time stable and keeps the boiler in the operating regimes It is recommended to use the built in equitherm regulation either in dependently or com...

Страница 14: ...we recommend not to mount thermostatic heads on radiators in the reference room at all 2 3 3 Operation of the boiler using built in equithermal regulation This regime is accessible in the boiler in t...

Страница 15: ...nds to the shift of the curve 0 C After inspection of the temperature of the heated space after approximately 24 hours it is possible to perform additional setting according to all requirements for th...

Страница 16: ...ked In the case of any increase above 86 C the burning is stopped and circulating pump remains active The reignition is in the case of a decrease of the temperature under 80 C The working phase of the...

Страница 17: ...stat within the range 0 10 minutes may only be performed by an authorized service technician Notification All the above mentioned security and registered functions are in activity only if the boiler i...

Страница 18: ...s by rough handling for damage caused by unprofessional intervention into the electronic system during the adjustment and connection of the add in regulation for damages caused by the use of other par...

Страница 19: ...ol on the commissioning of THERM products into operation 6 Application for registration into the prolonged warranty programme 7 Confirmation of completing 1 and 2 service inspection 8 Hanging bar incl...

Страница 20: ...hane polystyrene polyethylene PVC etc The safe distance between flammable items and the boiler is 50mm from the chimney flue and the control hole 200mm Flammable items must not be located at lower dis...

Страница 21: ...m Due to the optimal use of the condensing regime of the boiler it is recommended to design heating systems for low temperatures t 50 30 C The minimum overpressure of the system is 0 8 bar We recommen...

Страница 22: ...0 Heating systems in buildings Design and assembly The producer requires mount into the slides of the pump filter and de sludge equipment e g Spirovent Kal mount a bypass valve in heating systems with...

Страница 23: ...ss of all joints 3 7 Filling and discharging of the heating system When filling the heating system the boiler must be disconnected from the electricity network by disconnecting the fork from the socke...

Страница 24: ...ases of these types of boilers must be designed by means of the certificate smoke collection system delivered by the producer From the viewpoint of checking the route for burnt gases it is necessary t...

Страница 25: ...t has voltage free contact can be used i e no other voltage is supplied into the boiler It is necessary to connect the room thermostat to the boiler by a two core conductor The recommended cross secti...

Страница 26: ...must not be grounded to the body in several places For example a SYKFY cable is recommended Construction C 13 axial horizontal variant with termination to the peripheral wall The piping can be double...

Страница 27: ...tart and mixture ration are adjusted by the service technician during start up of the boiler by means of the flue gas analyser The gas fitting is set exclusively by an employee of the authorized servi...

Страница 28: ...28 THERM 90 KD A 4 2 Electrical connection diagram...

Страница 29: ...er alloys are collected into the sorted metal collection units The thermal insulation of the combustion chamber is harmless to health and is disposed of in common communal wastes For storage it is nec...

Страница 30: ...n burner power consumption Pign kW In standby mode PSB kW Emissions of nitrogen oxides NOx mg kWh Sound power level indoors LWA dB For combination heaters Water heating energy efficiency class Water h...

Страница 31: ...Slovak Republic EC notified body identification number 202 THERM 90 KD A Certificate of testing of the model according to the EC Directive for consumer appliances for gas fuel 2009 142 EEC No E 30 01...

Страница 32: ...THERMONA spol s r o Star osada 258 664 84 Zast vka u Brna 420 544 500 511 FAX 420 544 500 506 thermona thermona cz www thermona cz THERMONA 2016 09 2016...

Отзывы: