10
THERM 90 KD.A
Multi-functional buttons
– designated for the diagnostics and setting of he parameters of the boiler exclusively by
a service technician or for switching off information data (see below)
Manometer
– displays the measured water pressure in the heating system
Indication of set temperature
After turning the control knob for setting the temperature of the heating system or DHW (boilers with flow heating of DHW)
the respective symbol of the regime will start to flash along with the numeric display of the temperature on the LCD display.
In this case, the value of the last temperature set is indicated. After the termination of the setting, the indication of the set
temperature remains for about 5 seconds. The following permanent display of the numeric value and the symbol, the real
temperature of the respective regime is indicated again.
reset
2.1.2 LCD display
Setting the water temperature
– not used, only active when using the machine to heat the solar accumulation reservoir.
The water temperature for THERM 90 KD.A boilers connected to the standard reservoir is set directly on the thermostat
for the reservoir.
Disconnection of water heating
– setting the rotary control knob for user setting of the output temperature of the
hot water to the left side position (less than 10° of the route); the heating of water can be in winter mode permanently
disconnected from operation.
option to disconnect the water heating
detail