background image

o

Warm protection

If for some reason overcome

 92 C 

circulator is activated and lowers 

o

the temperature of the boiler 

88 C.

Protection Circuit

:

Page

  3 / 5

Burners off

:

                               -  

If short-circuit fault appears in the sensor

.

                             -  

If sensor is being cut

.

                             -  

If sensor for any reason stops working

.

                      

Temperature variation

 [

sensor is removed from its position

).                               

o

Frost protection

If the boiler temperature drops to

 +2 C 

the burner is automatically 

o

activated  and raises the temperature of the boiler to

 +8 C.

Circulator protection

Automatic activation of the circulator at time periods in order to 

avoid obstacles

ÔÊÁ

ÔÊÕ

BR

ÊÁ

ÊY

LINE

LINE

GRD

N

HEATING COMMAND 

 

[01]

HOT WATER COMMAND

 [02]

PHASE OF 
ROOM THERMOSTAT 

[03]

WHEN BURNER STOPS

 [05]

BURNER PHASE

 [06]

GROUNDING

 [10]

NEUTRAL
ROOM THERMOSTAT 

 [04]

CIRCULATOR PHASE  

 [

07]

NEUTRAL
BURNER

-

CIRCULATOR

  

[08]

GROUNDING
BURNER

-

CIRCULATOR  

 

[09]

NEUTRAL   

 

[11]

ÖÁÓÇ 

[12]

M

aster 

 B

oiler 

 

Control panel link 

 

Feeding voltage

AC 220V - 50Hz

Internal safety of the control panel

F 5A

 /

 220V

ISO 9001 - CE** - ISCIR

MANUAL

 

MASTER BOILER 

03062005 

PUBLISH

: 1 

DATE

 03062005