Operating instructions and electrological connection of control panel
M
aster Boiler
BUTTON
01
BUTTON
04
BUTTON
03
BUTTON
02
LAMP
02
LAMP
01
LAMP
03
LAMP
04
DISPLAY
LAMP
05
BUTTON
01:
Increases the indication we wish to regulate
.
BUTTON
02:
Decreases the indication we wish to regulate
.
BUTTON
03:
Choose the parameter to regulate it
.
PARAMETERS
:
t 1 :
Temperature where the burner stops
.
d 1 :
Low hysteresis of the burner temperature t1
.
t 2 :
Temperature where the circulator starts
The operation of heating
d 2 :
Low hysteresis of the circulator temperature t2
t 3 :
temperature where the circulator starts the
Operation of hot water and heating
simultaneously
d 3 :
Low hysteresis of the circulator temperature t3
S t :
Application
BUTTON
04:
Switch
ON / OFF
of the boiler
DISPLAY
shows
:
-
the temperature of the boiler when it is standing
-
Parameters in the programming
-
any damages of the boiler
LAMP
01:
lights when the boiler operates
LAMP
02:
lights when the circulator operates
LAMP
03:
lights when the circuit protection is activated
LAMP
04:
lights when the burner block
LAMP
05:
lights when the boiler is activated
Programming
:
Press
for
2’’
continiously
SET
to enter the programming. With up and down arrows
adjust the parameters
.
To go to the next parameter press
SET.
When you get to sign
S t
has finished
programming
.
After this procedure, temperature appears again on the display
.
o
o
Recommended parameter values
:
t 1 : 72 C d 1 : 2 C
o
o
t 2 : 45 C d 2 : 2 C
o
o
t 3 : 64 C d 3 : 2 C
Page
2 / 5
Notice
:
All the control panels are preset from the factory
ISO 9001 - CE** - ISCIR
MANUAL
MASTER BOILER
03062005
PUBLISH
: 1
DATE
: 03062005