For the installation of 

 

M

aster boiler the following hardware need to be connected

:

1. 

Expansion tank (24lt) in the heating circuit or bigger than that if it is required by the installation. 

  

2. 

Safety valve

 1/2"  3BAR.

3. 

Automatic air vent of 

 2 

pieces or more depending on the installation

.

4. 

Filling valve

 ½” 

with manometer

.

5. 

Magnesium anode for protection against salt

.

6. 

Blackflow prevender in hot water circuit

.

7. 

Expansion tank (

8

lt) in hot sanitary water circuit

.

8. 

Pressure reducer in hot sanitary water circuit since we have increased pressure in our network.

 M

aster 

iler connection

1. 

The hydraylic connection of the boiler is based on a project and you can find it on this booklet as 

well as at back side of the boiler.

2. 

You should avoid connecting the boiler tuborama with the hot water circuit.

 

3. 

The electrical cinnection is based on the diagram of the manual.

Boiler settings

1. 

The pressure of the heating circuit should be regulated by

 1-1,5 BAR.

2. 

For proper and economical operation the setting of the burner should be done by a licensed 

technician.

 

3. 

The temperature at which the burner stops is preset.

4. 

The temperature at which the circulator stops is preset.

 

Boiler maintenance

1. 

It is necessary the annual cleaning of the boiler as well as cleaning and adjusting the burner by a 

licensed burner technician.

2. 

It is also necessary a periodic cleaning of the heat exchanger (coil) to prevent icing salts. 

Otherwise, alternator will be blocked. The cleaning is done by special liquids that you can find in the 
market. Time of regular cleaning depends on the hardness of the water and the frequency of use of 
the boiler. 

Room thermostat installation

 1. Ô

hermostat should be placed in the room that concerns us more the changes in temperature.

 

 2. 

Thermostat should not be placed near a radiator, in  front of a wall that just behind a radiator is 

located or in a wall that tubes exists.

 3. 

Also not to be placed near a window or a balcony door.