Thermocet Hi-Fire Ligero Скачать руководство пользователя страница 7

Page 7 

3.10 Setting the flame size / Extinguishing the fire  

After the burner is ignited, the flame size will automatically move into the maximum setting.  

Press to 

reduce the flame size and turn off the burner. 

(Extinguishing the fire: “

STAND BY

”). (Pressing the key for a short time gradually reduces the flame.)  

Press to 

increase the flame. (Pressing the key for a short time gradually increases the flame.)

 

  

 

3.11 Switching the unit off.

 

 

Press    to reduce the flame size and turn the burner off (“

STAND BY

”).  

Then press the                        

OFF key to turn the entire unit off, including the pilot flame.  

If the unit is not used for an extended period of time, you can turn the "

O I

” switch, on the gas control 

block, into the “

O

” position, in order to save battery life.  

In this case, it is also recommended you close the gas shut-off cock in the supply line.

 

  

 

Important: 

If, for whatever reason, the pilot light extinguishes, you must wait 5 minutes before igniting 

the pilot light again.   

 

 

           Malfunction

   

If the signals from the manual transmitter are not received adequately by the receiver, this may be caused 
by:  

Flat batteries: replace the batteries.  

An electronic problem: can be solved by pressing the "

RESET

” key on the receiver.  

Contact your fitter if the unit regularly turns off.

 

  

 

3.12 Replacing the batteries

 

  

The batteries of the manual transmitter and receiver have a life span of approximately one year. The use of 
alkaline batteries is recommended.  

The batteries need to be replaced when the following occur:  

           1. Manual transmitter: BATT appears on the display.  
           2. Receiver: long sound signals can be heard during the ignition.

 

  

 
1. Manual transmitter:  

Open the small lid on the back.  

Carefully remove the 9V block battery and loosen the battery from the contact holder. Do not pull the 
wires!  

Connect the new battery and place it back into the transmitter. Close the lid.

 

 

 

2. Receiver:   

Carefully remove the entire receiver from the holder.  

Slide the small lid open.  

Remove the batteries from the battery holder.  

Place 4 new 1.5V batteries (type LR6 or AA) in the battery holder in the indicated manner. The spring 
always needs to be against the minus (-) pole of the battery.  

Close the lid and place the receiver back into the holder. 

  
Incorrect placing of the batteries can irreparably damage the electronics or power.  

 

Only replace the batteries when the unit is completely turned off.   
 
 

Содержание Hi-Fire Ligero

Страница 1: ...Page 1 OPERATING AND INSTALLATION INSTRUCTIONS HI FIRE COLLECTION BASE UNIT GREAT BRITTAN GB IRELAND IE...

Страница 2: ...nstallation instructions regarding existing flues 7 4 Parts 7 5 Installation 7 6 Cleaning and maintenance 8 Instructions for the Mertik Maxitrol GV60 and the Remote Control Page 16 9 Maintenance check...

Страница 3: ...ll and or some smoke to be emitted Any deposit on the heat resistant glass should be removed immediately using a fireplace cleaner suitable for heat resistant glass Attention The unit must be installe...

Страница 4: ...the unit continues to operate safely For additional instructions see Chapter 3 Maintenance If for whatever reason the pilot light extinguishes you must wait 5 minutes before igniting the pilot light...

Страница 5: ...ait a moment or press OFF to return to MAN mode 3 5 Setting the desired temperature Press the SET key briefly to select the required mode or Keep the SET key pressed in until the screen starts flashin...

Страница 6: ...n Simultaneously push the keys OFF and on the manual transmitter A short sound signal will confirm commencement Short sound signals will then follow until the pilot flame and main burner are ignited A...

Страница 7: ...d by Flat batteries replace the batteries An electronic problem can be solved by pressing the RESET key on the receiver Contact your fitter if the unit regularly turns off 3 12 Replacing the batteries...

Страница 8: ...wn for another 10 seconds and then let go Important If the pilot light extinguishes one should wait at least 5 minutes before repeating the aforementioned steps Turn the operating button to the ON pos...

Страница 9: ...d fireplaces Prevent discolouration of walls and ceilings There are always particles in the air in each living area even if the area is vacuum cleaned regularly These particles are easily visible when...

Страница 10: ...cal information for the relevant country needs to be consulted and modifications discussed with the manufacturer There will be air in the gas pipes when the unit is first used The gas pipes therefore...

Страница 11: ...ength The outlet can be installed at any point on the roof face or exterior wall supply and discharge in an identical pressure area but must meet applicable regulations Duct pathways may not be insula...

Страница 12: ...king any hindrance to the surrounding area into consideration according to national regional local standards and regulations Ensure wind pressure on the flue terminal is not too extreme such as a balc...

Страница 13: ...between rooms See national regional local standards and regulations A casing made of fireproof material e g 12 mm Promatect fire resistant plate must be used at 25mm from the outside duct Determine th...

Страница 14: ...90 to 165 8 Existing brickwork duct 9 Mounting plate on the roof square 300 10 Clamping strip supplied with 11 11 Roof pass through Note The renovation sanitation set consists of parts 3 4 5 7 and 9...

Страница 15: ...Page 15 A B...

Страница 16: ...erformed at a later date This may be more difficult if the control is installed using a method that is different from the instructions provided here Please note Only place the batteries after wiring t...

Страница 17: ...ton using a blunt object See photograph 3 Continue to press this button until you hear a short beeping sound followed immediately by a long beeping signal Release the button Direct the manual transmit...

Страница 18: ...Page 18...

Страница 19: ...Name Address Unit serial number Date of purchase Installation date Comments 9 0 MAINTENANCE CHECK UP LIJST Fitter details Service date Performed by Work activities performed Service and maintenance l...

Страница 20: ...he inspection replace decorative parts exactly as stipulated by the manufacturer Ensure the pilot burner is kept free e check if the pilot flame protection is intact if applicable f check the piezo fo...

Страница 21: ...quipment 11 3 Placing ceramic wood blocks See page 28 Please note You need to check if a restriction plate needs to be mounted before the wood blocks are placed See page 22 Remove the gas clamps hold...

Страница 22: ...e vertically on the unit Next continue building up the flue pipe using two 45 bends the calculation length for each bend is 1 metre until you have reached the maximum pipe length of 12 metres includin...

Страница 23: ...H I2E I2E I2L I3B P I3B P I3B P I3P I3P I3P PRIMAIRE AIR INLET 2 x 6 5 2 x 4 4 3 x 13 3 x 13 3 x 13 2 x 13 1 x 5 2 x 13 1 x 5 2 x 13 1 x 5 PRE PRESSURE mBAR 20 Mbar 25 Mbar 28 30 Mbar 30 Mbar 50 Mbar...

Страница 24: ...cannot be adjusted there may be an obstruction in the pilot 2 Check whether the thermocouple interrupter is connected to the gas valve prop erly 3 Check that the gas valve is not faulty 4 Check whethe...

Страница 25: ...Page 25 1...

Страница 26: ...Page 26 1 2 1 7 1 6 1 5 1 4 1 3...

Страница 27: ...Page 27 A E B C D F I H G K L J M N O...

Страница 28: ...Page 28 E D C B A...

Страница 29: ...Page 29...

Страница 30: ...Page 30 3 1 G 2 G 1 H I P O P O 2...

Страница 31: ...Page 31...

Страница 32: ...Pag 32 TTI d o o Thermo Technology International...

Отзывы: