11. PLACING THE UNIT (first read “General instructions”)

 

 

 

Please note: Before placing the unit, we recommend you first read Chapter 7 “Concentric flue system” on 
page 11.

 

 

 

11.1 Round and level unit components (See page 25 )

 

 

 

A.

                Combustion chamber                       

J.

                 Remote control  

B.

                 Burner plate                                      

K.               

Decoration plate 

C.

                Gas control block                             

L.

                Gas clamps 

D.

                Receiver                                            

M.

               Window 

E.

                 Burner                                               

N.               

Wall plate/radiation plate 

F.

                 Ceramic wall at the back                 

O.               

Restriction plate 

G.

                Ceramic wall at the top                    

P.               

Restriction plate Ø 65 

H.

                Ceramic wall on the left                  

Q.               

pilot flame cover 

I.

                  Ceramic wall on the right

 

                 

 

11.2 Connection to the gas pipes

 

 

 

You can determine where the gas pipes will be placed, dependent on the layout. Ensure control equipment is not 
twisted during installation and there is no excessive tension. Accessibility of various connection points in relation 
to components need to be maintained. After installation, check the connections for tightness in relation to gas. 
Use a 1/2“ gas tap with connection. Ensure the gas pipes are dirt-free and sand-free, and gas and combustion 
products from various parts and functioning is correct. The gas connection should only be undertaken when the 
electricity supply is disconnected. This prevents any damage occurring to the gas control equipment.  

 
 

11.3   Placing ceramic wood blocks (See page 28 )

 

 

 

Please note! 
You need to check if a restriction plate needs to be mounted before the wood blocks are placed. (See 
page 22)

 

 

Remove the gas clamps (hold the window back) to the left, right and at the top of the unit. Screw the 
bottom clamp(s) a little looser so the window is still supported and the window can be easily removed from 
the unit. Place the window somewhere safe.  

After the window has been removed, the log inset can be placed. To this end, please see the photo’s on page 
28 outlining the order in which items are placed.  

Firstly, mix the Lava stones and the so-called ‘wokkels’ (worm-shaped 

ceramic burner decoration material) 

and distribute these over the burner and decoration plate. Ensure the ventilation slot around the burner and 
pilot burner are taken into account, as these need to be kept free from decoration material.

  

 

Warning! 

Do not place ceramic burner decoration material or logs against the pilot burner.

 

 

 

Carefully place the log inset. Different positions may have a significant influence on the flame image or 
cause poor functioning of the burning process.  

For maintenance activities (to the burner, pilot flame or thermocouple), the window can be removed by 
dismantling the gas clamps as described above. Remove the ceramic logs one log at a time and replace 
these once maintenance has been performed as described above.  

Replace the window and carefully fasten the gas clamps.

 

 

 

 

Содержание Hi-Fire Ligero

Страница 1: ...Page 1 OPERATING AND INSTALLATION INSTRUCTIONS HI FIRE COLLECTION BASE UNIT GREAT BRITTAN GB IRELAND IE...

Страница 2: ...nstallation instructions regarding existing flues 7 4 Parts 7 5 Installation 7 6 Cleaning and maintenance 8 Instructions for the Mertik Maxitrol GV60 and the Remote Control Page 16 9 Maintenance check...

Страница 3: ...ll and or some smoke to be emitted Any deposit on the heat resistant glass should be removed immediately using a fireplace cleaner suitable for heat resistant glass Attention The unit must be installe...

Страница 4: ...the unit continues to operate safely For additional instructions see Chapter 3 Maintenance If for whatever reason the pilot light extinguishes you must wait 5 minutes before igniting the pilot light...

Страница 5: ...ait a moment or press OFF to return to MAN mode 3 5 Setting the desired temperature Press the SET key briefly to select the required mode or Keep the SET key pressed in until the screen starts flashin...

Страница 6: ...n Simultaneously push the keys OFF and on the manual transmitter A short sound signal will confirm commencement Short sound signals will then follow until the pilot flame and main burner are ignited A...

Страница 7: ...d by Flat batteries replace the batteries An electronic problem can be solved by pressing the RESET key on the receiver Contact your fitter if the unit regularly turns off 3 12 Replacing the batteries...

Страница 8: ...wn for another 10 seconds and then let go Important If the pilot light extinguishes one should wait at least 5 minutes before repeating the aforementioned steps Turn the operating button to the ON pos...

Страница 9: ...d fireplaces Prevent discolouration of walls and ceilings There are always particles in the air in each living area even if the area is vacuum cleaned regularly These particles are easily visible when...

Страница 10: ...cal information for the relevant country needs to be consulted and modifications discussed with the manufacturer There will be air in the gas pipes when the unit is first used The gas pipes therefore...

Страница 11: ...ength The outlet can be installed at any point on the roof face or exterior wall supply and discharge in an identical pressure area but must meet applicable regulations Duct pathways may not be insula...

Страница 12: ...king any hindrance to the surrounding area into consideration according to national regional local standards and regulations Ensure wind pressure on the flue terminal is not too extreme such as a balc...

Страница 13: ...between rooms See national regional local standards and regulations A casing made of fireproof material e g 12 mm Promatect fire resistant plate must be used at 25mm from the outside duct Determine th...

Страница 14: ...90 to 165 8 Existing brickwork duct 9 Mounting plate on the roof square 300 10 Clamping strip supplied with 11 11 Roof pass through Note The renovation sanitation set consists of parts 3 4 5 7 and 9...

Страница 15: ...Page 15 A B...

Страница 16: ...erformed at a later date This may be more difficult if the control is installed using a method that is different from the instructions provided here Please note Only place the batteries after wiring t...

Страница 17: ...ton using a blunt object See photograph 3 Continue to press this button until you hear a short beeping sound followed immediately by a long beeping signal Release the button Direct the manual transmit...

Страница 18: ...Page 18...

Страница 19: ...Name Address Unit serial number Date of purchase Installation date Comments 9 0 MAINTENANCE CHECK UP LIJST Fitter details Service date Performed by Work activities performed Service and maintenance l...

Страница 20: ...he inspection replace decorative parts exactly as stipulated by the manufacturer Ensure the pilot burner is kept free e check if the pilot flame protection is intact if applicable f check the piezo fo...

Страница 21: ...quipment 11 3 Placing ceramic wood blocks See page 28 Please note You need to check if a restriction plate needs to be mounted before the wood blocks are placed See page 22 Remove the gas clamps hold...

Страница 22: ...e vertically on the unit Next continue building up the flue pipe using two 45 bends the calculation length for each bend is 1 metre until you have reached the maximum pipe length of 12 metres includin...

Страница 23: ...H I2E I2E I2L I3B P I3B P I3B P I3P I3P I3P PRIMAIRE AIR INLET 2 x 6 5 2 x 4 4 3 x 13 3 x 13 3 x 13 2 x 13 1 x 5 2 x 13 1 x 5 2 x 13 1 x 5 PRE PRESSURE mBAR 20 Mbar 25 Mbar 28 30 Mbar 30 Mbar 50 Mbar...

Страница 24: ...cannot be adjusted there may be an obstruction in the pilot 2 Check whether the thermocouple interrupter is connected to the gas valve prop erly 3 Check that the gas valve is not faulty 4 Check whethe...

Страница 25: ...Page 25 1...

Страница 26: ...Page 26 1 2 1 7 1 6 1 5 1 4 1 3...

Страница 27: ...Page 27 A E B C D F I H G K L J M N O...

Страница 28: ...Page 28 E D C B A...

Страница 29: ...Page 29...

Страница 30: ...Page 30 3 1 G 2 G 1 H I P O P O 2...

Страница 31: ...Page 31...

Страница 32: ...Pag 32 TTI d o o Thermo Technology International...

Отзывы: