Thermocet Hi-Fire Ligero Скачать руководство пользователя страница 5

Page 5 

3.       REMOTE CONTROL   

 

3.1     General   

 

The unit is operated using a radio-controlled remote control. This consists of a manual transmitter and a 
receiver. The receiver is connected to the gas control block.   

*        The receiver and gas control block are located at the bottom of the unit.   

 

3.2     Manual transmitter

 

  

 

The transmitter uses a radio-controlled signal. The signal code is set at the factory, but can be adjusted if 
required. (See 3.7)  

 

3.3     Screen setup

 

 

 

After fitting the batteries, simultaneous pressing of 

OFF 

and 

allows you to  

change from °F (and 12-hour clock) to °C (and 24-hour clock), or vice versa.  

Wait a moment or press 

OFF

 to return to 

MAN

 mode.  

 

3.4     Time setup

 

 

 

*        For 

SET

 mode or program mode, simultaneously press 

and    

*        The time can be set while the screen is flashing.   
*        Press 

to input the hour and  

to input the minutes.  

*        Wait a moment or press 

OFF

 to return to 

MAN

 mode.   

 

3.5     Setting the desired temperature

  

 

Press the 

SET 

-key briefly to select the required 

mode or     

Keep the 

SET 

–key pressed in until the screen starts flashing.  

Subsequently press  

or     to set the required temperature.  

Wait a moment or briefly press the 

OFF 

-key to select the

 MAN

 mode.  

If the temperature setting needs to be switched off with   

(low battery usage), then lower  

until    

appears on the screen.  

 

 

3.6     Setting the timer: P1 and P2  

 

 

Press briefly on the 

SET 

-key to select the required mode   

Keep the 

SET 

–key pressed in until P1   (heating period 1) flashes on the screen.  

Set the commencement time of the first (1

st

) heating period by pressing on to 

input the hour,  and on   

to input the minutes.  

Briefly press the 

SET 

-key; P1 now appears on the screen. Set the time the first (1

st

) heating period needs 

to end.   

Press the 

SET 

-key again to set the beginning and end of the second (2

nd 

) heating period P2  

(

ON

) and 

P2 (

OFF

).  

Wait a moment or press 

OFF

 to return to 

MAN

 mode.

   

 

Manual transmitter

  

 

 

Содержание Hi-Fire Ligero

Страница 1: ...Page 1 OPERATING AND INSTALLATION INSTRUCTIONS HI FIRE COLLECTION BASE UNIT GREAT BRITTAN GB IRELAND IE...

Страница 2: ...nstallation instructions regarding existing flues 7 4 Parts 7 5 Installation 7 6 Cleaning and maintenance 8 Instructions for the Mertik Maxitrol GV60 and the Remote Control Page 16 9 Maintenance check...

Страница 3: ...ll and or some smoke to be emitted Any deposit on the heat resistant glass should be removed immediately using a fireplace cleaner suitable for heat resistant glass Attention The unit must be installe...

Страница 4: ...the unit continues to operate safely For additional instructions see Chapter 3 Maintenance If for whatever reason the pilot light extinguishes you must wait 5 minutes before igniting the pilot light...

Страница 5: ...ait a moment or press OFF to return to MAN mode 3 5 Setting the desired temperature Press the SET key briefly to select the required mode or Keep the SET key pressed in until the screen starts flashin...

Страница 6: ...n Simultaneously push the keys OFF and on the manual transmitter A short sound signal will confirm commencement Short sound signals will then follow until the pilot flame and main burner are ignited A...

Страница 7: ...d by Flat batteries replace the batteries An electronic problem can be solved by pressing the RESET key on the receiver Contact your fitter if the unit regularly turns off 3 12 Replacing the batteries...

Страница 8: ...wn for another 10 seconds and then let go Important If the pilot light extinguishes one should wait at least 5 minutes before repeating the aforementioned steps Turn the operating button to the ON pos...

Страница 9: ...d fireplaces Prevent discolouration of walls and ceilings There are always particles in the air in each living area even if the area is vacuum cleaned regularly These particles are easily visible when...

Страница 10: ...cal information for the relevant country needs to be consulted and modifications discussed with the manufacturer There will be air in the gas pipes when the unit is first used The gas pipes therefore...

Страница 11: ...ength The outlet can be installed at any point on the roof face or exterior wall supply and discharge in an identical pressure area but must meet applicable regulations Duct pathways may not be insula...

Страница 12: ...king any hindrance to the surrounding area into consideration according to national regional local standards and regulations Ensure wind pressure on the flue terminal is not too extreme such as a balc...

Страница 13: ...between rooms See national regional local standards and regulations A casing made of fireproof material e g 12 mm Promatect fire resistant plate must be used at 25mm from the outside duct Determine th...

Страница 14: ...90 to 165 8 Existing brickwork duct 9 Mounting plate on the roof square 300 10 Clamping strip supplied with 11 11 Roof pass through Note The renovation sanitation set consists of parts 3 4 5 7 and 9...

Страница 15: ...Page 15 A B...

Страница 16: ...erformed at a later date This may be more difficult if the control is installed using a method that is different from the instructions provided here Please note Only place the batteries after wiring t...

Страница 17: ...ton using a blunt object See photograph 3 Continue to press this button until you hear a short beeping sound followed immediately by a long beeping signal Release the button Direct the manual transmit...

Страница 18: ...Page 18...

Страница 19: ...Name Address Unit serial number Date of purchase Installation date Comments 9 0 MAINTENANCE CHECK UP LIJST Fitter details Service date Performed by Work activities performed Service and maintenance l...

Страница 20: ...he inspection replace decorative parts exactly as stipulated by the manufacturer Ensure the pilot burner is kept free e check if the pilot flame protection is intact if applicable f check the piezo fo...

Страница 21: ...quipment 11 3 Placing ceramic wood blocks See page 28 Please note You need to check if a restriction plate needs to be mounted before the wood blocks are placed See page 22 Remove the gas clamps hold...

Страница 22: ...e vertically on the unit Next continue building up the flue pipe using two 45 bends the calculation length for each bend is 1 metre until you have reached the maximum pipe length of 12 metres includin...

Страница 23: ...H I2E I2E I2L I3B P I3B P I3B P I3P I3P I3P PRIMAIRE AIR INLET 2 x 6 5 2 x 4 4 3 x 13 3 x 13 3 x 13 2 x 13 1 x 5 2 x 13 1 x 5 2 x 13 1 x 5 PRE PRESSURE mBAR 20 Mbar 25 Mbar 28 30 Mbar 30 Mbar 50 Mbar...

Страница 24: ...cannot be adjusted there may be an obstruction in the pilot 2 Check whether the thermocouple interrupter is connected to the gas valve prop erly 3 Check that the gas valve is not faulty 4 Check whethe...

Страница 25: ...Page 25 1...

Страница 26: ...Page 26 1 2 1 7 1 6 1 5 1 4 1 3...

Страница 27: ...Page 27 A E B C D F I H G K L J M N O...

Страница 28: ...Page 28 E D C B A...

Страница 29: ...Page 29...

Страница 30: ...Page 30 3 1 G 2 G 1 H I P O P O 2...

Страница 31: ...Page 31...

Страница 32: ...Pag 32 TTI d o o Thermo Technology International...

Отзывы: