Thermo Scientific Thermo Fisher 3900 Series Скачать руководство пользователя страница 22

Section 8 

Parts List 

 

 

Page 8-1 

Table  8-1. 

Parts List 

 

 

Description

 

3915LT /  3990LT

 

3923LT /  3994LT

 

3915FL /  3990FL 

 

3923FL /  3994FL 

 

Peltier device 

7010547 

7010547 

7010547 

7010547 

EMI filtered  fused inlet 

4200523 

4200523 

4200523 

4200523 

Cooling  fans  (2) 100-120V 

2600546 

N/A 

2600546 

N/A 

Cooling fans (2) 220-240V 

N/A 

2600547 

N/A 

2600547 

Access Port 

9580571 

9580571 

9580571 

9580571 

Power Supply 

6750517 

6750517 

6750517 

6750517 

Feet, Adjustable  Glide 

2700500 

2700500 

2700506 

2706506 

I/O (on/off) Switch 

7850570 

7850570 

7850570 

7850570 

Main  Temperature 

Controller 

9660514 / 9660510 

9660514 / 9660510 

9660514 / 9660510 

9660514 / 9660510 

Over Temperature  

Thermostat  (OTL) 

1750813 

1750813 

1750813 

1750813 

Pilot Light, Green 

4650554 

4650554 

4650554 

4650554 

Pilot Light, Red 

4650553 

4650553 

4650553 

4650553 

Power Cord, European 

N/A

 

1800500

 

N/A 

1800500 

Power  Cord, USA 

1800510 

N/A 

1800510 

N/A 

Optional Sliding Shelf 

Mount Left 

9490575 

9490575 

9490575 

9490575 

Optional Sliding Shelf 

Mount Right 

9490576 

9490576 

9490576 

9490576 

Shelf standard 

5220956 /  5220941 

5220956 /  5220941 

5220956 /  5220941 

5220956 /  5220941 

Shelf Mounting  Bracket 

5220942 

5220942 

5220942 

5220942 

Fuse 6.3A  T (2 required  on 

220-240v  unit) 

3300515 

3300515 

3300515 

3300515 

Knob for  OTL 

4450506 

4450506 

4450506 

4450506 

LED Light Bar 

4650547 

4650547 

4650547 

4650547 

Door Switch 

7850571 

7850571 

7850571 

7850571 

Содержание Thermo Fisher 3900 Series

Страница 1: ...User Manual Thermo Fisher Model 3900 Series Bod Fly Incubators Operating and Maintenance Manual 7003900 January 2013...

Страница 2: ...volatile or combustible materials are being heated These units have been tested to the requirements of CAN CSA C22 2 No 61010 1 second edition including Amendment 1 or a later version of the same stan...

Страница 3: ...nce must be performed by qualified service personnel Material in this manual is for information purposes only The contents and the product it describes are subject to change without notice Thermo Fish...

Страница 4: ...Temperature Protection Signale un d passement de temp rature Indicates AC Power Rep re secteur AC I Indicates the power is ON I Rep re de la position MARCHE de l interrupteur d alimentation O O Indica...

Страница 5: ...Preface iv...

Страница 6: ...Storing Offset Value for Day Cycle in Memory 4 6 Calibration Offsets for Day Cycle 4 6 Storing Offset Value for Night Cycle in Memory 4 7 Calibration Offsets for Night Cycle 4 7 Settingthe Real Time...

Страница 7: ...es and instructions in this manual may be dangerous and illegal General Safety Considerations Your incubator and its recommended accessories have been designed and tested to meet strict safety require...

Страница 8: ...e data plate at the rear of the unit Do not modify the power cord provided with the unit If the plug does not fit an outlet have a proper outlet installed by a qualified electrician Avoid damaging the...

Страница 9: ...er 2 2 Inspect for concealed loss or damage on the unit itself both interior and exterior If necessary the carrier will arrange for official inspection to substantiate your claim 2 3 Return Shipment S...

Страница 10: ...prevent loss of product due to overloading or circuit failure Note Electrical supply to the unit must conform to all national and local electrical codes 3 2 Location When selecting a site for the inc...

Страница 11: ...d bottom hooks into the provided slots on the sides of the chamber 3 6 Install Shelf Mounts and Shelves Install shelf mounts from the corner top and bottom hooks into the shelf standard in the chamber...

Страница 12: ...e material contained within If temperature rises to the OTL set point the OTL takes control of the peltier unit and prevents the temperature within the incubator from rising further until the problem...

Страница 13: ...ual Process Temperature Display Process Setpoint Display Output 1 Active Heating Element On 20 0C 20 0 1 2 3 EZ1 EZ2 Up Arrow Key Down Arrow Key Output 2 Active Output 3 Active Easy Zone Advance Key L...

Страница 14: ...Event output 2 Event Timer Factory installed timer internal gLbL Global menu HoUr Hour of day night i CA Calibration offset JC Jump Count JL Jump Loop JS Jump Step Min Minutes SoAH Soak oPEr Operatio...

Страница 15: ...LE WILL RUN THE LAST THREE STEPS ARE ENTERING THE NIGHT CYCLE START TIME IN HOURS AND MINUTES AND THE SET POINT WHICH THE NIGHT CYCLE WILL RUN BELOW ARE INSTRUCTIONS ON HOW TO SCROLL THROUGH THE 8 STE...

Страница 16: ...ic thermometer neither are supplied with your incubator in the center of the chamber Placing the reference thermometer in the chamber at this stage of operation will allow for calibrating the control...

Страница 17: ...s been made allow the unit temperature to stabilize before verifying the reference thermometer matches the setpoint Adjust again if necessary 5 5 Setting the Set Over Limit Temperature Control To set...

Страница 18: ...r should be cleaned and disinfected prior to use s 6 1 Cleaning Periodic cleaning is required To clean the incubator perform the following steps 6 1 1 Remove all of the interior parts if assembled 6 1...

Страница 19: ...infectants available that are non corrosive and non abrasive and suitable for use on painted surfaces Contact your local Site Safety Officer for detailed information for the proper disinfectants suita...

Страница 20: ...ify power cord is properly connected there is no loose or disconnected wiring and all control console devices are firmly seated Do not attempt to access the electrical compartment area unless you are...

Страница 21: ...er temperature unstable 1 0 1 may be normal 2 Are the internal and external fans working 3 Is ambient room temperature rapidly changing either door opening or room airflow from heaters or air conditio...

Страница 22: ...14 9660510 9660514 9660510 9660514 9660510 Over Temperature Thermostat OTL 1750813 1750813 1750813 1750813 Pilot Light Green 4650554 4650554 4650554 4650554 Pilot Light Red 4650553 4650553 4650553 465...

Страница 23: ...its 25 5 x 24 0 x 18 5 in 64 77 x 60 96 x 46 99 cm both units 25 5 x 24 0 x 54 5 in 64 77 x 60 96 x 138 43cm both units 25 5 x 24 0 x 54 5 in 64 77 x 60 96 x 138 43cm both units Capacity 6 55 cubic fe...

Страница 24: ...3 4 1 T1 S1 R1 T1 S1 R1 X1 W1 Y1 W Y L3 K3 J3 L4 K4 98 99 CF CD CE B5 D6 D5 WATLOW PM 9660514 RTD SENSOR 6600520 2 3 4 1 2 3 4 1 2 3 4 1 A B C D BROWN BROWN BLUE RED 14G RED 18G BLACK 18G BLACK 14G R...

Страница 25: ...3 4 1 T1 S1 R1 T1 S1 R1 X1 W1 Y1 W Y L3 K3 J3 L4 K4 98 99 CF CD CE B5 D6 D5 WATLOW PM 9660514 RTD SENSOR 6600520 2 3 4 1 2 3 4 1 2 3 4 1 A B C D BROWN BROWN BLUE RED 14G RED 18G BLACK 18G BLACK 14G R...

Страница 26: ...2 L3 K3 J3 L4 K4 98 99 CF CD CE B5 D6 D5 WATLOW PM 9660514 RTD SENSOR 6600520 2 3 4 1 2 3 4 1 2 3 4 1 A B C D BROWN BROWN BLUE RED 14G RED 18G BLACK 18G BLACK 14G RED 22G RED 22G BLACK22G BLACK22G YEL...

Страница 27: ...2 L3 K3 J3 L4 K4 98 99 CF CD CE B5 D6 D5 WATLOW PM 9660514 RTD SENSOR 6600520 2 3 4 1 2 3 4 1 2 3 4 1 A B C D BROWN BROWN BLUE RED 14G RED 18G BLACK 18G BLACK 14G RED 22G RED 22G BLACK22G BLACK22G YEL...

Страница 28: ...R SWITCH 7850571 LED LIGHT BAR 2 3 4 1 T1 S1 R1 T1 S1 R1 X1 W1 Y1 W Y L3 K3 J3 L4 K4 98 99 CF CD CE B5 D6 D5 WATLOW PM 9660510 RTD SENSOR 6600520 2 3 4 1 2 3 4 1 2 3 4 1 A B C D BROWN BROWN BLUE RED 1...

Страница 29: ...3 4 1 T1 S1 R1 T1 S1 R1 X1 W1 Y1 W Y L3 K3 J3 L4 K4 98 99 CF CD CE B5 D6 D5 WATLOW PM 9660510 RTD SENSOR 6600520 2 3 4 1 2 3 4 1 2 3 4 1 A B C D BROWN BROWN BLUE RED 14G RED 18G BLACK 18G BLACK 14G RE...

Страница 30: ...2 L3 K3 J3 L4 K4 98 99 CF CD CE B5 D6 D5 WATLOW PM 9660510 RTD SENSOR 6600520 2 3 4 1 2 3 4 1 2 3 4 1 A B C D BROWN BROWN BLUE RED 14G RED 18G BLACK 18G BLACK 14G RED 22G RED 22G BLACK22G BLACK22G YEL...

Страница 31: ...99 CF CD CE B5 D6 D5 WATLOW PM 9660510 RTD SENSOR 6600520 2 3 4 1 2 3 4 1 2 3 4 1 A B C D BROWN BROWN BLUE RED 14G RED 18G BLACK 18G BLACK 14G RED 22G RED 22G BLACK22G BLACK22G YELLOW ORANGE SSR RELA...

Страница 32: ...Thermo Fisher Scientific 401 Millcreek Road Marietta Ohio 45750 United States www thermofisher com...

Отзывы: