Operator Guide
49
Conveyor Error
Error Message / Symptom
Possible Cause
Remedy
Cassette misfeed on Conveyor.
Open the Print Door and
remove any visible Cassette.
Use the Touch Panel or PC
to continue.
Conveyor error
Cassette Clamp not retracting fully.
Press the top of the Clamp
Solenoid down and then
release.
The central bolt should
return to the top position.
If it does not return fully,
place a Cassette on the
Conveyor and manually
move it under the Cassette
Clamp.
If the Cassette touches the
Cassette Clamp it is faulty.
Call the Thermo Fisher
Scientific Service
Department.