Chapter 4
Alarms Management
User Manual - Haas Mini Mill
AA83766
2
Alarms List
All alarms managed by the system are listed below with:
♦
Alarm number.
♦
The alarm texte corresponding to the display on the screen.
♦
The category of thealarm.
♦
An explination of the alarm.
♦
Correcting action.
♦
Possible remarkses.
1
Power off or emergency stop
1
Explanations
Power off
Controled by input I0.0
Acknowledge
Automatic when powered on
Corrections
♦
Check whether other messages are displayed and take actions
♦
Check that no ES are pressed
♦
Check that either the door (relay 32K0) or robot door (relay 33K0) is closed
♦
Ccheck that the PLC output Q10.1 (PLC OK) is activated. If not, a message should
explain the reason.
♦
Check that the relays 30K7 and 30K8, driven by Q10.1 output are activated.
♦
Check if the 30K4 and 30K5 relays (ES) are ok.
♦
Check if the 30K0 relay is ok.
Remarks
2
Amplifier default
4
Explanations
The sample support amplifier is in error
Acknowledge
By the operator
Corrections
♦
Check 10Q6 circuit breaker
♦
Check RDY and COM led on the amplifier 10A3
♦
Check that the sample support did not hit anything
Remarks
Содержание Haas Mini Mill
Страница 1: ...Haas Mini Mill User Manual AA83766 ...
Страница 2: ......
Страница 4: ......
Страница 7: ...TABLE OF CONTENT ...
Страница 8: ......
Страница 11: ...1 INTRODUCTION ...
Страница 12: ......
Страница 15: ...2 MACHINE OPERATION ...
Страница 16: ......
Страница 30: ......
Страница 31: ...3 DIALOGUE BOXES DESCRIPTION ...
Страница 32: ......
Страница 53: ...4 ALARMS MANAGEMENT ...
Страница 54: ......
Страница 55: ...4 ALARMS MANAGEMENT ...
Страница 56: ......
Страница 66: ......
Страница 67: ......