All installations and services must be performed by qualified service personnel.
63
CLQS1-125T (Single Stage with Constant Torque blower motor)
Temperature Rise (°F)
External Static Pressure (in WC)
Speed Tap
0.1
0.2
0.3
0.4
0.5
0.6
0.7
Low (Red)
73
76
81
86
93
99
106
Med Low (Purple)
68
71
74
78
83
87
93
Med (Blue)
62
64
67
70
73
77
81
Med High (Yellow)
59
61
63
65
68
71
75
High (Black)
53
54
55
57
58
60
63
Airflow (CFM)
External Static Pressure (in WC)
Speed Tap
0.1
0.2
0.3
0.4
0.5
0.6
0.7
Low (Red)
1512
1444
1365
1275
1180
1111
1038
Med Low (Purple)
1625
1553
1481
1414
1330
1263
1186
Med (Blue)
1767
1710
1649
1582
1513
1437
1359
Med High (Yellow)
1878
1813
1753
1685
1617
1544
1463
High (Black)
2093
2047
1988
1938
1882
1819
1745
Current (A)
External Static Pressure (in WC)
Speed Tap
0.1
0.2
0.3
0.4
0.5
0.6
0.7
Low (Red)
4.4
4.6
4.7
4.8
4.9
5.0
5.1
Med Low (Purple)
5.2
5.4
5.5
5.6
5.7
5.9
6.0
Med (Blue)
6.0
6.3
6.4
6.5
6.7
6.8
7.0
Med High (Yellow)
6.3
6.6
6.7
6.8
7.0
7.1
7.3
High (Black)
8.7
8.9
9.0
9.3
9.5
9.7
9.7
Power (W) *
External Static Pressure (in WC)
Speed Tap
0.1
0.2
0.3
0.4
0.5
0.6
0.7
Low (Red)
386
402
412
427
439
447
457
Med Low (Purple)
464
480
493
506
517
529
540
Med (Blue)
543
566
580
592
607
622
636
Med High (Yellow)
578
600
611
626
642
656
670
High (Black)
810
830
843
866
886
901
919
Note: Shading indicates recommended operating range for heating.
* Includes 135W to power controls.
Cooling Unit
HTG Speed
Recommended CLG Speed
36,000
Med High (Yellow)
Low (Red)
42,000
Med High (Yellow)
Med Low (Purple)
48,000
Med High (Yellow)
Med (Blue)
60,000
Med High (Yellow)
High (Black)
Alterations Req'd For A/C @ Design External Static Pressure
Содержание CLQS1-050T36N
Страница 2: ......
Страница 4: ......
Страница 47: ...All installations and services must be performed by qualified service personnel 45...
Страница 55: ...All installations and services must be performed by qualified service personnel 53...
Страница 56: ...All installations and services must be performed by qualified service personnel 54...
Страница 57: ...All installations and services must be performed by qualified service personnel 55...
Страница 59: ...All installations and services must be performed by qualified service personnel 57...
Страница 60: ...All installations and services must be performed by qualified service personnel 58...