Electrical Maintenance (Rev 6/98)
41
The voltage at the B+ terminal should be 13 to 18 volts
and the amperage in the 2A wire should be at least as
high as the rated output of the alternator.
NOTE: An alternator can easily exceed its rated out-
put. An alternator MUST at least reach its rated out-
put when full fielded. An alternator that has a
defective rectifier diode may reach 75% of its rated
output with a full field.
14. Stop the unit.
15. Use the readings obtained previously to determine the
problem by referring to the Diagnosis Chart.
NOTE: This assumes that the alternator did not
charge properly prior to the full field test.
Field Current Test (Checks the field windings,
brushes and slip rings)
Perform this test with the On-Off switch in the OFF posi-
tion.
1.
Attach a clamp-on ammeter to the 2A wire near the B+
terminal on the alternator.
Diagnosis Chart
Amperage in 2A
Voltage at B+
Problem/Solution
At or above rated output
At or above battery voltage and
increasing
Voltage regulator defective / Replace volt-
age regulator and brush assembly
Approximately 60% of
rated output
Approximately equal to battery voltage
and does not change, or rises slightly
Receiver diode defective / Repair or
replace alternator
Low or no output
Less than or equal to battery voltage
and decreasing
Stator windings, field windings, brush or
diode defective / Perform Field Current Test
to check brushes and field coil, or replace
alternator
2.
Connect a jumper wire between the F2 terminal on the
alternator and a chassis ground, and note the ammeter
reading.
3.
The ammeter reading indicates field current. The fol-
lowing chart shows the field current for each alternator
with 12 volts applied to the field:
a.
No field current or a low field current indicates an
open circuit or excessive resistance in the field cir-
cuit. Replace the voltage regulator and brush
assembly, inspect the slip rings and repeat the test.
If the brushes are not the problem, replace the rotor
or the alternator.
b.
High field current indicates a short in the field cir-
cuit. Repair or replace the alternator.
Alternator Rating
Field Current
@ 12 Volts
23 Amp
1.0 to 3.0 Amps
37 Amp
3.5 to 4.5 Amps
65 Amp
4.0 to 5.0 Amps
Содержание Super II SR+
Страница 4: ......
Страница 10: ...ii ...
Страница 14: ...4 ...
Страница 22: ...Unit Description Rev 6 98 12 Front View AEA1350 ...
Страница 23: ...Unit Description Rev 6 98 13 Right Side Door Open AEA1351 ...
Страница 24: ...Unit Description Rev 6 98 14 Left Side Doors Open AEA1352 ...
Страница 26: ...Operating Instructions Rev 6 98 16 Control Box Cover AEA1354 ...
Страница 34: ...24 ...
Страница 42: ...Electronic Controls Rev 6 98 32 SOFTWARE REVISION 04XX ALARMS AEA1358 ...
Страница 82: ...72 ...
Страница 90: ...80 ...
Страница 116: ...106 ...
Страница 120: ...110 ...
Страница 130: ...120 ...
Страница 141: ...131 Schematic Diagram SBIII SII RMNII 30 SR MPIV ...
Страница 142: ...132 Wiring Diagram SII SBIII RMN30 SR MPIV Page 1 of 4 ...
Страница 143: ...133 Wiring Diagram SII SBIII RMN30 SR MPIV Page 2 of 4 ...
Страница 144: ...134 Wiring Diagram SII SBIII RMN30 SR MPIV Page 3 of 4 ...
Страница 145: ...135 Wiring Diagram SII SBIII RMN30 SR MPIV page 4 of 4 ...