Electronic Controls (Rev 6/98)
35
SERVICE TEST MODE NOTES
CAUTION:
Service Test Mode should be
used only by qualified technicians. Service
Test Mode should never be used for temperature
control or emergency operation.
•
The service test mode allows the unit to be forced to a
known operating condition regardless of setpoint or
temperature sensor inputs. This allows service person-
nel to troubleshoot the system under defined condi-
tions.
•
The unit will remain in any service test mode function
for 15 minutes if no other test mode function is
selected. At the end of 15 minutes it no other test mode
is selected the unit will shut down and record alarm
code 54 (service test shut down).
•
If the CYCLE-SENTRY-Continuous switch is set to
CONTINUOUS the engine may be either stopped or
running before entering service test mode. The engine
may be started in the usual manner at any time from
within service test mode as required.
•
If the CYCLE-SENTRY-Continuous switch is set to
CYCLE-SENTRY and the engine is running when
entering service test mode, it will remain running. If the
engine is not running, it will automatically start after
entering service test mode.
•
The hours, oil press, water temp, amps, SELECT,
CODE and CLEAR keys function normally when in
service test mode.
•
The protection circuits such as low oil pressure, high
engine temperature and high discharge pressure func-
tion normally when in service test mode.
•
The unit will not enter service test mode if it is in pre-
trip mode, defrost mode or sleep mode.
•
If a Shut Down Alarm occurs, the unit will record the
alarm, shut down and exit service test mode.
•
If the On-Off switch is OFF the unit will exit service
test mode.
Service Test Mode Functions
*Available only on units equipped with
modulation
Display Code
Definition
HSC
High Speed Cool
LSC
Low Speed Cool
LSH
Low Speed Heat
HSH
High Speed Heat
DEF
Defrost
CBYP*
Cool Bypass
MBO.5*
50% Mod Cool Bypass
MB1.0*
100% Mod Cool Bypass
MCO.5*
50% Mod Cool
MC1.0*
100% Mod Cool
MH0.5*
50% Mod Cool
MH1.0*
100% Mod Heat
Содержание Super II SR+
Страница 4: ......
Страница 10: ...ii ...
Страница 14: ...4 ...
Страница 22: ...Unit Description Rev 6 98 12 Front View AEA1350 ...
Страница 23: ...Unit Description Rev 6 98 13 Right Side Door Open AEA1351 ...
Страница 24: ...Unit Description Rev 6 98 14 Left Side Doors Open AEA1352 ...
Страница 26: ...Operating Instructions Rev 6 98 16 Control Box Cover AEA1354 ...
Страница 34: ...24 ...
Страница 42: ...Electronic Controls Rev 6 98 32 SOFTWARE REVISION 04XX ALARMS AEA1358 ...
Страница 82: ...72 ...
Страница 90: ...80 ...
Страница 116: ...106 ...
Страница 120: ...110 ...
Страница 130: ...120 ...
Страница 141: ...131 Schematic Diagram SBIII SII RMNII 30 SR MPIV ...
Страница 142: ...132 Wiring Diagram SII SBIII RMN30 SR MPIV Page 1 of 4 ...
Страница 143: ...133 Wiring Diagram SII SBIII RMN30 SR MPIV Page 2 of 4 ...
Страница 144: ...134 Wiring Diagram SII SBIII RMN30 SR MPIV Page 3 of 4 ...
Страница 145: ...135 Wiring Diagram SII SBIII RMN30 SR MPIV page 4 of 4 ...