Operating Instructions
39
c. Enter the new setpoint by pressing the
E
NTER
key within 5 seconds.
3. Initiate a Pretrip Test (refer to the appropriate
Operator’s Manual or Microprocessor
Diagnosis Manual for detailed information
about the pretrip). This procedure is automatic
and can be performed on the way to the
loading area or while waiting to load.
a. Place all the On/Off switches in the On
position.
b. Clear any alarms.
c. Press and hold the
TK
key for at least 3
seconds.
•
PRE TRIP will appear on the display.
d. Press the
E
NTER
key while PRE TRIP is
displayed.
•
PRE LOAD will appear on the display
and the pretrip test will start.
•
PRE AMPS will appear on the display
indicating that the amps check is
running and the pretrip has started.
•
The amps check will continue for
several minutes, then the unit will start
automatically and the operational tests
will be performed.
4. When the Pretrip Test is complete, PASS,
CHECK, or FAIL will appear on the display
until a function key (e.g.,
S
ELECT
or
E
NTER
) is
pressed. Continue as follows:
•
PASS—The unit is running and no alarms
have been recorded. The unit has passed
the pretrip. Go to step 6.
•
CHECK—The unit is running but Check
Alarms have been recorded. Go to step 5.
•
FAIL—The unit has shut down, recorded
Alarm Code 28, and possibly recorded
other Shutdown Alarms. Go to step 5.
5. View the Alarms with the
C
ODE
key (refer to
the appropriate Microprocessor Diagnosis
Manual for detailed information about
alarms).
a. Correct the alarm conditions.
b. Clear the alarms with the
C
LEAR
key (refer
to the appropriate Microprocessor
Diagnosis Manual for detailed information
about alarms).
c. Repeat the Pretrip Test until PASS appears
(the unit passes the pretrip).
6. Recheck the setpoints.
7. Complete the “After Start Inspection” on
Selection of Operating Modes
The Thermo King CYCLE-SENTRY system is
designed to save refrigeration fuel costs. The
savings vary with the commodity, ambient
temperatures and trailer insulation. However, not
all temperature controlled products can be
properly transported using CYCLE-SENTRY
operation. Certain highly sensitive products
normally require continuous air circulation.
The microprocessor has a CYCLS screen, which
is used to select CYCLE-SENTRY (CYCLS
YES) or Continuous Run (CYCLS No) operation.
Refer to the appropriate Operator’s Manual or
Microprocessor Diagnosis Manual for more
information about CYCLE-SENTRY selection.
Your selection of the operating mode for the
proper protection of a particular commodity
should use the following guidelines:
Examples of Products Normally
Acceptable for CYCLE-SENTRY Operation
•
Frozen foods (in adequately insulated trailers)
•
Boxed or processed meats
•
Poultry
•
Fish
•
Dairy products
•
Candy
•
Chemicals
•
Film
•
All non-edible products
Содержание Spectrum DE 30-2
Страница 4: ...4...
Страница 12: ...Safety Precautions 12...
Страница 16: ...Specifications 16...
Страница 31: ...Unit Description 31 1 Access Panels 2 Defrost Dampers Figure 12 Back View of Unit 1 2 AGA215...
Страница 42: ...Operating Instructions 42...
Страница 48: ...Electrical Maintenance 48...
Страница 106: ...Structural Maintenance 106...
Страница 110: ...Mechanical Diagnosis 110...
Страница 114: ...Remote Evaporator Specifications 114...
Страница 116: ...Remote Evaporator Maintenance Inspection Schedule 116...
Страница 122: ...Remote Evaporator Electrical Maintenance 122...
Страница 126: ...Remote Evaporator Refrigeration Service Operations 126...
Страница 128: ...Remote Evaporator Structural Maintenance 128...
Страница 130: ...Remote Evaporator System Diagnosis 130...
Страница 134: ...Wiring and Schematic Diagrams Index 134...
Страница 135: ...135 Schematic Diagram Page 1 of 2...
Страница 136: ...136 Schematic Diagram Page 2 of 2...
Страница 137: ...137 Wiring Diagram Page 1 of 4...
Страница 138: ...138 Wiring Diagram Page 2 of 4...
Страница 139: ...139 Wiring Diagram Page 3 of 4...
Страница 140: ...140 Wiring Diagram Page 4 of 4...