Unit Description
20
Spectrum Remote Evaporator
A Spectrum Remote Evaporator is mounted on the
ceiling of the remote compartment to provide
temperature control Zone 3 (if used). A Spectrum
Remote Evaporator with two fans is called an S-2.
A Spectrum Remote Evaporator with three fans is
called an S-3.
Figure 3: S-3 Spectrum Remote Evaporator
Thermo King TK 486 Engine
The unit uses a quiet running Thermo King
TK 486, 4-cylinder, water cooled, direct injection
diesel engine. The TK 486 displaces 2.09 liters
and is rated at 33.9 horsepower (25.3 kilowatts) at
2200 rpm. The engine is connected directly to the
compressor. Belts transmit power to the fans,
alternator, and water pump.
Thermo King X430L
Compressor
The unit is equipped with a Thermo King X430L,
four-cylinder compressor with 30 cu. in.
(492 cm
3
) displacement. The unit is also equipped
with a compressor oil filter.
Units built before mid-February 2003 are
equipped with compressors that have a 4-quart
sump. Units built after mid-February 2003 are
equipped with compressors that have a 7-quart
sump. See “Compressor Sump Sizes” on page 73.
Smart Reefer Multi-Temp µP-IV
Microprocessor
The Smart Reefer Multi-Temp µP-IV is a
microprocessor control system designed for a
Smart Reefer Multi-Temp transport refrigeration
system. The Smart Reefer Multi-Temp µP-IV
integrates the following functions: thermostats,
digital thermometers, hourmeters, oil pressure
gauge, water temperature gauge, ammeter,
voltmeter, tachometer, mode indicator,
refrigeration system controller, and diagnostic
system.
The CYCLE-SENTRY
TM
system and integral
defrost timers are standard features. DAS and a
remote control box are optional features.
The microprocessor mounts inside a weather tight
control box. The display is clearly visible through
a transparent cover. Opening the keypad door
provides quick access to the microprocessor
keypad. The keypad is used to control the
operation of the microprocessor.
AJA984
Содержание Spectrum DE 30-2
Страница 4: ...4...
Страница 12: ...Safety Precautions 12...
Страница 16: ...Specifications 16...
Страница 31: ...Unit Description 31 1 Access Panels 2 Defrost Dampers Figure 12 Back View of Unit 1 2 AGA215...
Страница 42: ...Operating Instructions 42...
Страница 48: ...Electrical Maintenance 48...
Страница 106: ...Structural Maintenance 106...
Страница 110: ...Mechanical Diagnosis 110...
Страница 114: ...Remote Evaporator Specifications 114...
Страница 116: ...Remote Evaporator Maintenance Inspection Schedule 116...
Страница 122: ...Remote Evaporator Electrical Maintenance 122...
Страница 126: ...Remote Evaporator Refrigeration Service Operations 126...
Страница 128: ...Remote Evaporator Structural Maintenance 128...
Страница 130: ...Remote Evaporator System Diagnosis 130...
Страница 134: ...Wiring and Schematic Diagrams Index 134...
Страница 135: ...135 Schematic Diagram Page 1 of 2...
Страница 136: ...136 Schematic Diagram Page 2 of 2...
Страница 137: ...137 Wiring Diagram Page 1 of 4...
Страница 138: ...138 Wiring Diagram Page 2 of 4...
Страница 139: ...139 Wiring Diagram Page 3 of 4...
Страница 140: ...140 Wiring Diagram Page 4 of 4...