107
Mechanical Diagnosis
Condition
Possible Cause
Remedy
Engine will not crank
Electrical problem
Check and repair electrical system
Defective starter solenoid
Replace solenoid
Defective starter
Repair starter
Water in cylinders
Check for hydrostatic lock. Remove
injectors and turn engine slowly
Starter motor turns but engine
does not crank
Starter clutch defective
Replace
Engine cranks but fails to start
Fuel solenoid not energized
Check 8D and 8DP circuits and fuel
solenoid relay. Check that YAN =
YES in Super Guarded Access.
Refer to appropriate Microprocessor
Diagnostic Manual.
Fuel solenoid defective or stuck
Replace
Fuel injection pump defective
Replace pump
Air heater defective
Replace
No fuel or wrong fuel
Fill with proper fuel
Fuel pump defective
Replace pump
Air in fuel system
Bleed air
Compression low
Overhaul engine
Injection nozzles defective
Replace nozzles
Incorrect timing
Adjust timing
Air cleaner clogged
Replace air filter
Exhaust plugged
Clean exhaust
Defective HPCO
Replace HPCO
Engine stops after starting
Air in injection pump
Bleed fuel system
Fuel filter obstructed
Replace filter element
High head pressure
Eliminate cause of high head
pressure
Vent of fuel tank obstructed
Unclog vent
Clogged fuel tank or fuel lines
Clean fuel tank and fuel lines
Engine does not develop full
power
Air intake system clogged
Clean air intake system
Fuel tank vent clogged
Unclog vent
Clogged fuel tank or fuel lines
Clean fuel tank and fuel lines
Speed adjustment wrong
Adjust speed
Insufficient fuel volume leaving filter
Check for dirty filter or air in system
Air cleaner clogged
Replace air filter
Delivery of fuel pump insufficient
Repair pump
Injection pump timing off
Adjusting timing
Injection nozzles defective
Repair or replace nozzles
Compression low or unbalanced
Overhaul engine
Worn injection pump plungers,
delivery valve defective, injection
rate too low, gum formations
Repair or replace pump
Содержание Spectrum DE 30-2
Страница 4: ...4...
Страница 12: ...Safety Precautions 12...
Страница 16: ...Specifications 16...
Страница 31: ...Unit Description 31 1 Access Panels 2 Defrost Dampers Figure 12 Back View of Unit 1 2 AGA215...
Страница 42: ...Operating Instructions 42...
Страница 48: ...Electrical Maintenance 48...
Страница 106: ...Structural Maintenance 106...
Страница 110: ...Mechanical Diagnosis 110...
Страница 114: ...Remote Evaporator Specifications 114...
Страница 116: ...Remote Evaporator Maintenance Inspection Schedule 116...
Страница 122: ...Remote Evaporator Electrical Maintenance 122...
Страница 126: ...Remote Evaporator Refrigeration Service Operations 126...
Страница 128: ...Remote Evaporator Structural Maintenance 128...
Страница 130: ...Remote Evaporator System Diagnosis 130...
Страница 134: ...Wiring and Schematic Diagrams Index 134...
Страница 135: ...135 Schematic Diagram Page 1 of 2...
Страница 136: ...136 Schematic Diagram Page 2 of 2...
Страница 137: ...137 Wiring Diagram Page 1 of 4...
Страница 138: ...138 Wiring Diagram Page 2 of 4...
Страница 139: ...139 Wiring Diagram Page 3 of 4...
Страница 140: ...140 Wiring Diagram Page 4 of 4...