Alarm Codes
148
Corrective Action
The operator can repair certain faults, other faults can only be
repaired by your Thermo King Dealer. The operator can clear
some alarm codes, but some alarm codes (3, 4, 74, 203, and
204) can only be cleared by a technician. Contact your
supervisor or a Thermo King dealer about clearing those
alarms. Refer to the table on the following pages for the proper
corrective action.
NOTE: Document all alarm faults and report them to the
service technician.
There are three levels of corrective action that can be taken
when an alarm condition occurs.
OK To Run:
An alarm condition exists but does not affect
unit operation. Corrective action can occur at a later date.
Check As Specified:
An alarm condition exists that could
affect unit operation. Follow directions in the Corrective
Action column on the following chart.
Take Immediate Action:
An alarm condition exists that
will damage the unit or load. Take immediate action to correct
the problem.
NOTE: The corrective actions listed above and on the
following chart are suggestions only. Always consult your
company for final decisions.
NOTE: The chart on the following pages shows all possible
alarm codes for all possible applications. Not all codes will be
applicable to each individual unit.
Alarm Codes
148
Corrective Action
The operator can repair certain faults, other faults can only be
repaired by your Thermo King Dealer. The operator can clear
some alarm codes, but some alarm codes (3, 4, 74, 203, and
204) can only be cleared by a technician. Contact your
supervisor or a Thermo King dealer about clearing those
alarms. Refer to the table on the following pages for the proper
corrective action.
NOTE: Document all alarm faults and report them to the
service technician.
There are three levels of corrective action that can be taken
when an alarm condition occurs.
OK To Run:
An alarm condition exists but does not affect
unit operation. Corrective action can occur at a later date.
Check As Specified:
An alarm condition exists that could
affect unit operation. Follow directions in the Corrective
Action column on the following chart.
Take Immediate Action:
An alarm condition exists that
will damage the unit or load. Take immediate action to correct
the problem.
NOTE: The corrective actions listed above and on the
following chart are suggestions only. Always consult your
company for final decisions.
NOTE: The chart on the following pages shows all possible
alarm codes for all possible applications. Not all codes will be
applicable to each individual unit.
Содержание SB-210+
Страница 1: ...Operator s Manual SB 210 SB 310 Operator s Manual SB 210 SB 310 TK 53942 2 OP Rev 1 11 09 ...
Страница 13: ...12 Introduction 12 ...
Страница 23: ...22 EPA Emission Control System Warranty Statement 22 ...
Страница 45: ...44 Remote Status Display Optional 44 ...
Страница 109: ...108 Figure 77 Pretrip Test Screen Sequence Operating Instructions 108 Figure 77 Pretrip Test Screen Sequence SELECT Key ...
Страница 117: ...116 Operating Instructions 116 1 Product Setpoint Soft Key Figure 85 Standard Display with Product Setpoint Soft Key 1 ...
Страница 129: ...128 Operating Instructions 128 ...
Страница 189: ...188 Maintenance Inspection Schedule 188 ...
Страница 191: ...190 Warranty 190 ...
Страница 205: ...204 Serial Number Locations 204 ...