![Thermo King SB-210+ Скачать руководство пользователя страница 155](http://html1.mh-extra.com/html/thermo-king/sb-210/sb-210_operators-manual_1104425155.webp)
Alarm Codes
154
41
Check Engine Coolant
Temperature
If unit is shutdown, repair immediately. Otherwise, report
alarm at end of day.
X
42
Unit Forced to Low Speed
Report alarm at end of day.
X
43
Unit Forced to Low Speed
Modulation
Report alarm at end of day.
X
44
Out of Fuel
Unit has been shut down. Refill fuel tank.
X
X
45
Hot Gas Bypass or Hot Gas
Bypass Circuit
If unit is shutdown repair immediately. Otherwise, report
alarm at end of day.
X
46
Check Air Flow
Cargo may be restricting air flow, check load. Report alarm
at end of day.
X
47
Remote Sensor Shutdown
The unit is no longer able to operate and has been shut
down. Repair immediately.
X
Table of Alarm Codes
NOTE: Not all alarm codes are available with all microprocessor controllers or all revisions of software.
Code Description
Corrective Action
Level Of
Action
Ok T
o
Run
Check
Shut
Down
Alarm Codes
154
41
Check Engine Coolant
Temperature
If unit is shutdown, repair immediately. Otherwise, report
alarm at end of day.
X
42
Unit Forced to Low Speed
Report alarm at end of day.
X
43
Unit Forced to Low Speed
Modulation
Report alarm at end of day.
X
44
Out of Fuel
Unit has been shut down. Refill fuel tank.
X
X
45
Hot Gas Bypass or Hot Gas
Bypass Circuit
If unit is shutdown repair immediately. Otherwise, report
alarm at end of day.
X
46
Check Air Flow
Cargo may be restricting air flow, check load. Report alarm
at end of day.
X
47
Remote Sensor Shutdown
The unit is no longer able to operate and has been shut
down. Repair immediately.
X
Table of Alarm Codes
NOTE: Not all alarm codes are available with all microprocessor controllers or all revisions of software.
Code Description
Corrective Action
Level Of
Action
Ok T
o
Run
Check
Shut
Down
Содержание SB-210+
Страница 1: ...Operator s Manual SB 210 SB 310 Operator s Manual SB 210 SB 310 TK 53942 2 OP Rev 1 11 09 ...
Страница 13: ...12 Introduction 12 ...
Страница 23: ...22 EPA Emission Control System Warranty Statement 22 ...
Страница 45: ...44 Remote Status Display Optional 44 ...
Страница 109: ...108 Figure 77 Pretrip Test Screen Sequence Operating Instructions 108 Figure 77 Pretrip Test Screen Sequence SELECT Key ...
Страница 117: ...116 Operating Instructions 116 1 Product Setpoint Soft Key Figure 85 Standard Display with Product Setpoint Soft Key 1 ...
Страница 129: ...128 Operating Instructions 128 ...
Страница 189: ...188 Maintenance Inspection Schedule 188 ...
Страница 191: ...190 Warranty 190 ...
Страница 205: ...204 Serial Number Locations 204 ...