7. If a thermostat is demanding Cool or Heat, the
electric motor will start and the unit will
operate. The unit will not operate if the box
temperature is near the thermostat setpoint.
8. Check the fan rotation by holding a small
piece of cloth or paper in front of the
condenser grille. Correct fan rotation will
draw the cloth or paper toward the grille,
incorrect rotation will blow the cloth or paper
away.
9. If the fan rotation is correct, leave the unit
turned On.
10. If the rotation is incorrect, the phase of the
power supply is wrong and must be corrected.
Turn Off the power to the cable and reverse
the position of any two power leads from the
power cable plug. Do not disturb the green
ground wire. (Refer this procedure to a
qualified electrical repairman).
After Start Inspection
Compressor Oil:
The compressor oil level should
be visible in the sight glass.
Refrigerant:
Check the refrigerant charge, see
Refrigerant Charge in the Refrigeration
Maintenance chapter.
Thermostat:
Set the thermostat at, well above or
well below the compartment temperature. Check
to make sure that the mode of operation changes
with the change in setpoint.
Pre-Cooling:
With the thermostat set at the
required temperature, allow the unit to run for
one-half to one hour (longer if possible) before
loading the truck. Pre-cooling will remove
residual body heat and moisture from the truck
interior and provide a good test of the
refrigeration system.
Defrost:
When the unit has finished pre-cooling
the truck interior (evaporator coil temperature
below 42 F [6 C]), initiate Defrost cycle with the
M
ANUAL
D
EFROST
key. The Defrost cycle should end
automatically.
Loading Procedure
1. Make sure the unit is Off before opening the
doors to minimize frost accumulation on the
evaporator coil and heat gain in the truck.
(Unit may be running when loading the truck
from a warehouse with door seals.)
2. Spot check and record the load temperature
while loading. Especially note any
off-temperature product.
3. Load product so that there is adequate space
for air circulation completely around the load.
Do not block the evaporator inlet or outlet.
4. Products should be pre-cooled before loading.
Thermo King units are designed to maintain
loads at the temperature at which they were
loaded. Transport refrigeration units are not
designed to pull hot loads down to
temperature.
Post Load Procedure
1. Make sure all the doors are closed and locked.
2. Set the thermostat at the required temperature
setpoint.
3. Start the unit.
4. One-half hour after loading, Defrost each
evaporator by momentarily pressing the
Manual Defrost keys. If the evaporator coil
temperature has dropped below 42 F (6 C), the
unit will Defrost. The Defrost cycle should
stop automatically.
Post Trip Checks
1. Wash the unit.
2. Check for leaks.
3. Check for loose or missing hardware.
4. Check for physical damage to the unit.
Содержание 914970
Страница 3: ...3...
Страница 10: ...Table of Contents 10...
Страница 27: ...Unit Description 27 Unit Photographs Figure 1 Roadside View Figure 2 Curbside View PUB122 PUB123...
Страница 40: ...Operating Instructions 40...
Страница 82: ...Electronic Controls 82...
Страница 92: ...Electrical Maintenance 92...
Страница 124: ...Refrigeration Maintenance 124...
Страница 140: ...Hilliard Clutch Maintenance 140...
Страница 160: ...Refrigeration Diagrams 160...
Страница 163: ...Index 163 W wiring 85 wiring diagrams 165...
Страница 164: ...Index 164...
Страница 166: ...Wiring and Schematic Diagrams Index 166...
Страница 167: ...167 Cab Control RD Wiring Diagram...
Страница 168: ...168 RD w o Thermostat Cab Control Schematic...
Страница 169: ...169 RD Cab Box Wiring Diagram...
Страница 170: ...170 RD Cab Control w Thermostat Schematic Diagram...
Страница 171: ...171 RD 50 STD 3 Phase Wiring Diagram Page 1 of 2...
Страница 172: ...172 RD 50 STD 3 Phase Wiring Diagram Page 2 of 2...
Страница 173: ...173 RD 50 STD 3 Phase Schematic Diagram Page 1 of 2...
Страница 174: ...174 RD 50 STD 3 Phase Schematic Diagram Page 2 of 2...
Страница 175: ...175 RD 30 STD Wiring Diagram Page 1 of 2...
Страница 176: ...176 RD 30 STD Wiring Diagram Page 2 of 2...
Страница 177: ...177 RD 30 STD Schematic Diagram Page 1 of 2...
Страница 178: ...178 RD 30 STD Schematic Diagram Page 2 of 2...
Страница 179: ...179 RD 30 C S Wiring Diagram Page 1 of 2...
Страница 180: ...180 RD 30 C S Wiring Diagram Page 2 of 2...
Страница 181: ...181 RD w CYCLE SENTRY Schematic Diagram Page 1 of 2...
Страница 182: ...182 RD w CYCLE SENTRY Schematic Diagram Page 2 of 2...
Страница 183: ...183 RD 50 C S 3 Phase Wiring Diagram Page 1 of 2...
Страница 184: ...184 RD 50 C S 3 Phase Wiring Diagram Page 2 of 2...
Страница 185: ...185 RD w CYCLE SENTRY Schematic Diagram Page 1 of 2...
Страница 186: ...186 RD w CYCLE SENTRY Schematic Diagram Page 2 of 2...