Refrigeration Service Operations
127
Heat Exchanger
Removal
1. Remove the refrigerant charge.
2. Remove the evaporator top cover.
3. Remove the mounting bolts that hold the heat
exchanger on the bulkhead.
4. Disconnect the equalizer line from the suction
line.
5. Disconnect liquid outlet line flare nut from the
expansion valve.
6. Note the position of the feeler bulb on the side
of the suction line. Remove the expansion
valve feeler bulb from the suction tube.
7. Unsolder the suction line at the evaporator coil
end.
8. Unsolder the remaining outlet suction line and
inlet liquid line connections from the
condenser side of the bulkhead. Remove putty
from around the lines before unsoldering the
connections.
9. Lift the heat exchanger assembly out of the
evaporator housing.
Installation
1. Clean the tubes for soldering.
2. Place the heat exchanger assembly in the
evaporator housing and install the mounting
hardware loosely.
3. Solder liquid inlet and suction outlet line
connections on the condenser side of the
bulkhead. Seal openings through bulkhead
with putty when refrigerant lines have cooled
off.
4. Tighten the heat exchanger mounting
hardware securely.
5. Solder suction line connection to the
evaporator coil.
6. Connect the equalizer line flare fitting to the
suction line and liquid outlet line flare fitting
to the expansion valve.
7. Pressurize the low side and test for leaks. If no
leaks are found, evacuate the unit.
8. Clean the suction tube to a bright polished
condition. Install the feeler bulb clamps and
feeler bulb on the side of the suction line in its
former position. The feeler bulb must make
good contact with the suction line or operation
will be faulty. Wrap with insulating tape.
9. Open the refrigeration valves and place the
unit in operation. Install refrigerant charge.
10. Test the unit to see that the expansion valve is
properly installed.
High Pressure Cutout Switch
Removal
1. Install gauge manifold set.
2. Start the unit and pump down the low side.
3. Stop the unit.
4. Bleed high side to low side using gauge set.
5. Disconnect the wires and remove the high
pressure cutout switch from the discharge
tube.
Installation
1. Apply a refrigerant Loctite
TM
to the threads of
the high pressure cutout switch.
2. Install and tighten high pressure cutout switch
and reconnect the wires.
3. Pressurize the refrigeration system and test for
leaks. If no leaks are found, evacuate the
system.
High Pressure Relief Valve
Removal
1. Remove the refrigerant charge.
2. Unscrew and remove the high pressure relief
valve.
Installation
1. Apply a refrigerant Loctite
TM
to the threads of
the high pressure relief valve.
2. Install and tighten the high pressure relief
valve.
Содержание 914970
Страница 3: ...3...
Страница 10: ...Table of Contents 10...
Страница 27: ...Unit Description 27 Unit Photographs Figure 1 Roadside View Figure 2 Curbside View PUB122 PUB123...
Страница 40: ...Operating Instructions 40...
Страница 82: ...Electronic Controls 82...
Страница 92: ...Electrical Maintenance 92...
Страница 124: ...Refrigeration Maintenance 124...
Страница 140: ...Hilliard Clutch Maintenance 140...
Страница 160: ...Refrigeration Diagrams 160...
Страница 163: ...Index 163 W wiring 85 wiring diagrams 165...
Страница 164: ...Index 164...
Страница 166: ...Wiring and Schematic Diagrams Index 166...
Страница 167: ...167 Cab Control RD Wiring Diagram...
Страница 168: ...168 RD w o Thermostat Cab Control Schematic...
Страница 169: ...169 RD Cab Box Wiring Diagram...
Страница 170: ...170 RD Cab Control w Thermostat Schematic Diagram...
Страница 171: ...171 RD 50 STD 3 Phase Wiring Diagram Page 1 of 2...
Страница 172: ...172 RD 50 STD 3 Phase Wiring Diagram Page 2 of 2...
Страница 173: ...173 RD 50 STD 3 Phase Schematic Diagram Page 1 of 2...
Страница 174: ...174 RD 50 STD 3 Phase Schematic Diagram Page 2 of 2...
Страница 175: ...175 RD 30 STD Wiring Diagram Page 1 of 2...
Страница 176: ...176 RD 30 STD Wiring Diagram Page 2 of 2...
Страница 177: ...177 RD 30 STD Schematic Diagram Page 1 of 2...
Страница 178: ...178 RD 30 STD Schematic Diagram Page 2 of 2...
Страница 179: ...179 RD 30 C S Wiring Diagram Page 1 of 2...
Страница 180: ...180 RD 30 C S Wiring Diagram Page 2 of 2...
Страница 181: ...181 RD w CYCLE SENTRY Schematic Diagram Page 1 of 2...
Страница 182: ...182 RD w CYCLE SENTRY Schematic Diagram Page 2 of 2...
Страница 183: ...183 RD 50 C S 3 Phase Wiring Diagram Page 1 of 2...
Страница 184: ...184 RD 50 C S 3 Phase Wiring Diagram Page 2 of 2...
Страница 185: ...185 RD w CYCLE SENTRY Schematic Diagram Page 1 of 2...
Страница 186: ...186 RD w CYCLE SENTRY Schematic Diagram Page 2 of 2...