Refrigeration Service Operations
126
2. Remove the feeler bulb from the suction line
clamp. Note the position of the feeler bulb on
the suction line.
3. Unsolder the equalizer line from the
expansion valve.
4. Unsolder the inlet liquid line and the
distributor from the expansion valve.
5. Remove the expansion valve mounting bolt
and remove the expansion valve from the unit.
Installation
1. Install and bolt the expansion valve assembly
in the unit.
2. Solder (95-5 Solder) the inlet liquid line and
the distributor to the expansion valve.
3. Solder (95-5 Solder) the equalizer line to the
expansion valve.
4. Clean the suction line to a bright polished
condition. Install the feeler bulb clamps and
the feeler bulb on the side of the suction line
in its former position. The feeler bulb must
make good contact with the suction line or the
operation will be faulty. Wrap with insulating
tape.
5. Pressurize the low side and test for leaks. If no
leaks are found, evacuate the low side.
6. Open the refrigeration valves and place the
unit in operation.
7. Test the unit to see that the expansion valve is
properly installed.
Cleaning In-line Screen
1. Perform a low side pump down; bleed
pressure back to 1 psig (7 kPa).
2. Remove the liquid line fitting.
3. A small tool with a slight hook may be needed
to pull screen from the expansion valve.
4. Clean the screen and reinstall.
NOTE: Outlet screen points toward the
distributor.
1.
Suction Line
2.
Capillary Bulb
3.
End View
Figure 50: Location of Expansion Valve Bulb
1.
Top View
Figure 51: Completely Wrap Bulb with Tape
1.
Solder-in Expansion Valve Screen
2.
Solder-in Type
Figure 52: Expansion Valve
Содержание 914970
Страница 3: ...3...
Страница 10: ...Table of Contents 10...
Страница 27: ...Unit Description 27 Unit Photographs Figure 1 Roadside View Figure 2 Curbside View PUB122 PUB123...
Страница 40: ...Operating Instructions 40...
Страница 82: ...Electronic Controls 82...
Страница 92: ...Electrical Maintenance 92...
Страница 124: ...Refrigeration Maintenance 124...
Страница 140: ...Hilliard Clutch Maintenance 140...
Страница 160: ...Refrigeration Diagrams 160...
Страница 163: ...Index 163 W wiring 85 wiring diagrams 165...
Страница 164: ...Index 164...
Страница 166: ...Wiring and Schematic Diagrams Index 166...
Страница 167: ...167 Cab Control RD Wiring Diagram...
Страница 168: ...168 RD w o Thermostat Cab Control Schematic...
Страница 169: ...169 RD Cab Box Wiring Diagram...
Страница 170: ...170 RD Cab Control w Thermostat Schematic Diagram...
Страница 171: ...171 RD 50 STD 3 Phase Wiring Diagram Page 1 of 2...
Страница 172: ...172 RD 50 STD 3 Phase Wiring Diagram Page 2 of 2...
Страница 173: ...173 RD 50 STD 3 Phase Schematic Diagram Page 1 of 2...
Страница 174: ...174 RD 50 STD 3 Phase Schematic Diagram Page 2 of 2...
Страница 175: ...175 RD 30 STD Wiring Diagram Page 1 of 2...
Страница 176: ...176 RD 30 STD Wiring Diagram Page 2 of 2...
Страница 177: ...177 RD 30 STD Schematic Diagram Page 1 of 2...
Страница 178: ...178 RD 30 STD Schematic Diagram Page 2 of 2...
Страница 179: ...179 RD 30 C S Wiring Diagram Page 1 of 2...
Страница 180: ...180 RD 30 C S Wiring Diagram Page 2 of 2...
Страница 181: ...181 RD w CYCLE SENTRY Schematic Diagram Page 1 of 2...
Страница 182: ...182 RD w CYCLE SENTRY Schematic Diagram Page 2 of 2...
Страница 183: ...183 RD 50 C S 3 Phase Wiring Diagram Page 1 of 2...
Страница 184: ...184 RD 50 C S 3 Phase Wiring Diagram Page 2 of 2...
Страница 185: ...185 RD w CYCLE SENTRY Schematic Diagram Page 1 of 2...
Страница 186: ...186 RD w CYCLE SENTRY Schematic Diagram Page 2 of 2...