43
Electrical Maintenance
Australian Bosch Alternator -
Model 30
120 Amp Charging System
Diagnostic Procedures
NOTE: Units manufactured with
CYCLE-SENTRY and alternators with integral
regulators MUST use replacement alternators
with integral regulators.
Complete the following checkout procedure
before replacing the voltage regulator or the
alternator.
•
When testing alternators use accurate
equipment such as a Thermo King
P/N 204-615 (FLUKE 23) digital multimeter
and a Thermo King P/N 204-613 amp clamp
or an equivalent.
CAUTION: Full-fielding alternators with
the integral regulator is accomplished by
installing a jumper from terminal F2 to
ground. Attempting to full-field the
alternator by applying battery voltage to
terminal F2 will cause voltage regulator
failure.
CAUTION: The F7 fuse must be removed
from the relay board on units equipped
with the Australian Bosch alternator. The
voltage regulator will be damaged if the
unit is turned On with the F7 fuse in place
on the relay board.
1.
Check Point for 2A Amperage
3.
Check Point for Sense Circuit and
Excitation Circuit Voltages
2.
Check Point for B+ Voltage
4.
Position for Full Fielding Jumper
Figure 17: Check Points for Alternator Test
Содержание 002008
Страница 4: ...4 ...
Страница 25: ...Unit Description 25 Figure 3 Zone 1 Cool Zone 2 Cool and Zone 3 Cool Zone 3 Zone 2 Zone 1 AGA168 ...
Страница 27: ...Unit Description 27 Figure 4 Zone 1 Cool Zone 2 Cool and Zone 3 Heat Zone 3 Zone 2 Zone 1 AGA169 ...
Страница 30: ...Unit Description 30 Figure 9 Front View AJA920 ...
Страница 31: ...Unit Description 31 1 Access Panels 2 Defrost Damper Figure 10 Back View 1 2 ARA104 ...
Страница 114: ...Mechanical Diagnosis 114 ...
Страница 116: ...Electric Standby Diagnosis 116 ...
Страница 120: ...Remote Evaporator Specifications 120 ...
Страница 122: ...Remote Evaporator Maintenance Inspection Schedule 122 ...
Страница 128: ...Remote Evaporator Electrical Maintenance 128 ...
Страница 132: ...Remote Evaporator Refrigeration Service Operations 132 ...
Страница 134: ...Remote Evaporator Structural Maintenance 134 ...
Страница 136: ...Remote Evaporator System Diagnosis 136 ...
Страница 140: ...Index 140 ...
Страница 142: ......
Страница 143: ...143 Model 30 Schematic Diagram Page 1 of 2 ...
Страница 144: ...144 Model 30 Schematic Diagram Page 2 of 2 ...
Страница 145: ...145 Model 30 Wiring Diagram Page 1 of 4 ...
Страница 146: ...146 Model 30 Wiring Diagram Page 2 of 4 ...
Страница 147: ...147 Model 30 Wiring Diagram Page 3 of 4 ...
Страница 148: ...148 Model 30 Wiring Diagram Page 4 of 4 ...
Страница 149: ...149 Model 50 Schematic Diagram Page 1 of 2 ...
Страница 150: ...150 Model 50 Schematic Diagram Page 2 of 2 ...
Страница 151: ...151 Model 50 Wiring Diagram Page 1 of 5 ...
Страница 152: ...152 Model 50 Wiring Diagram Page 2 of 5 ...
Страница 153: ...153 Model 50 Wiring Diagram Page 3 of 5 ...
Страница 154: ...154 Model 50 Wiring Diagram Page 4 of 5 ...
Страница 155: ...155 Model 50 Wiring Diagram Page 5 of 5 ...