Structural Maintenance
106
Defrost Damper
Check the damper during scheduled maintenance
inspections for shaft wear, end play, and the
ability to stop the air flow.
Position the damper so that air flow is stopped on
the top and bottom edges with the solenoid
plunger bottomed out.
To adjust the damper:
1. Remove the damper assembly from the
evaporator.
2. Disconnect the damper link from the eye bolt.
3. Check Distance A, the distance from the
shoulder on the solenoid to the center of the
hole in the eye bolt. Distance A should be
2.75 in. (69.85 mm) with the solenoid
de-energized.
4. If necessary, adjust Distance A to the proper
dimension by loosening the locknut on the end
of the solenoid plunger and turning the eye
bolt. Tighten the locknut when Distance A is
correct.
5. Connect the damper link to the eye bolt.
6. Energize the solenoid (apply 12 volts dc) and
check the damper blade to make sure that both
edges contact the damper housing. If
necessary, adjust this by loosening the
solenoid mounting bolts and moving the
solenoid. Tighten the solenoid mounting bolts
when both edges of the damper blade contact
the damper housing.
7. Adjust the damper blade stops so they contact
the edges of the damper blade. This keeps the
damper from sticking closed.
1.
Stop
6.
Eye Bolt
2.
Mounting Bolts
7.
Round Stop
3.
Closed Position
8.
Distance A 2.75 in. (69.85 mm)
4.
Open Position
9.
Solenoid
5.
Damper Link
Figure 72: Defrost Damper Adjustment
AEA719
1
2
9
8
1
7
4
3
5
6
Содержание 002008
Страница 4: ...4 ...
Страница 25: ...Unit Description 25 Figure 3 Zone 1 Cool Zone 2 Cool and Zone 3 Cool Zone 3 Zone 2 Zone 1 AGA168 ...
Страница 27: ...Unit Description 27 Figure 4 Zone 1 Cool Zone 2 Cool and Zone 3 Heat Zone 3 Zone 2 Zone 1 AGA169 ...
Страница 30: ...Unit Description 30 Figure 9 Front View AJA920 ...
Страница 31: ...Unit Description 31 1 Access Panels 2 Defrost Damper Figure 10 Back View 1 2 ARA104 ...
Страница 114: ...Mechanical Diagnosis 114 ...
Страница 116: ...Electric Standby Diagnosis 116 ...
Страница 120: ...Remote Evaporator Specifications 120 ...
Страница 122: ...Remote Evaporator Maintenance Inspection Schedule 122 ...
Страница 128: ...Remote Evaporator Electrical Maintenance 128 ...
Страница 132: ...Remote Evaporator Refrigeration Service Operations 132 ...
Страница 134: ...Remote Evaporator Structural Maintenance 134 ...
Страница 136: ...Remote Evaporator System Diagnosis 136 ...
Страница 140: ...Index 140 ...
Страница 142: ......
Страница 143: ...143 Model 30 Schematic Diagram Page 1 of 2 ...
Страница 144: ...144 Model 30 Schematic Diagram Page 2 of 2 ...
Страница 145: ...145 Model 30 Wiring Diagram Page 1 of 4 ...
Страница 146: ...146 Model 30 Wiring Diagram Page 2 of 4 ...
Страница 147: ...147 Model 30 Wiring Diagram Page 3 of 4 ...
Страница 148: ...148 Model 30 Wiring Diagram Page 4 of 4 ...
Страница 149: ...149 Model 50 Schematic Diagram Page 1 of 2 ...
Страница 150: ...150 Model 50 Schematic Diagram Page 2 of 2 ...
Страница 151: ...151 Model 50 Wiring Diagram Page 1 of 5 ...
Страница 152: ...152 Model 50 Wiring Diagram Page 2 of 5 ...
Страница 153: ...153 Model 50 Wiring Diagram Page 3 of 5 ...
Страница 154: ...154 Model 50 Wiring Diagram Page 4 of 5 ...
Страница 155: ...155 Model 50 Wiring Diagram Page 5 of 5 ...