List of user parameters

Menu

Par. 

No.

Description

Range

Default 

setting

UM

Main menu

0000

013

Quick adjustment of direct Zone/Zone 1 heating setpoint in 0 

and 3 heating modes.

By connecting the zone control accessory, this parameter can 

be used to quickly change direct Zone/Zone 1 setpoint. This 

parameter simultaneously modifies the value of Par. 2103.

See Par. 2103

See Par. 

2103

°C

0000

023

Quick adjustment of Zone 2 heating setpoint in 0 and 3 heating 

modes.

By connecting the zone control accessory, this parameter can 

be used to quickly change Zone 2 setpoint. This parameter 

simultaneously modifies the value of Par. 2203.

See Par. 2203

See Par. 

2203

°C

0000

033

Quick adjustment of Zone 3 heating setpoint in 0 and 3 heating 

modes.

By connecting the zone control accessory, this parameter can 

be used to quickly change Zone 3 setpoint. This parameter 

simultaneously modifies the value of Par. 2303.

See Par. 2303

See Par. 

2303

°C

0000

047

Quick adjustment of DHW setpoint with heater

This parameter is only visible with Par. 2035 = 1

See Par. 2047

°C

0000

048

Quick adjustment of DHW setpoint with instant production

This parameter is only visible with Par. 2035 = 10

See Par. 2048

°C

0000

201

Stops the venting function

0 = No action

1 = Stop venting

Visible only when de-aeration is in operation

0…1

0

Info menu

1000

1001 CH flow temperature

°C

1000

1002 Domestic hot water temperature

°C

1000

1003 Domestic cold water temperature

This parameter is only visible with Par. 2035 = 10

°C

1000

1004 Outdoor temperature

°C

1000

1007 Return temperature

°C

1000

1033 System pressure

bar

1000

1056 Total hours of operation in heating mode

h x 10

1000

1057 Total hours of operation in domestic mode

h x 10

1000

1058 Total hours of operation

h x 10

1000

1062 Function not implemented

1000

1063 Input signal 0-10V

V

1000

1090

Counts down the days to the next service (if it’s past, a nega-

tive value is shown)

If the value is < 15 the service icon flashes

Days

1000

1101 Direct Zone/Zone 1 delivery temperature

°C

1000

1102 Direct Zone/Zone 1 ambient temperature

°C

1000

1112 Zone 1 heating setpoint

°C

1000

1201 Zone 2 delivery temperature

°C

1000

1202 Zone 2 ambient temperature

°C

1000

1212 Zone 2 heating setpoint

°C

1000

1301 Zone 3 delivery temperature

°C

1000

1302 Zone 3 ambient temperature

°C

1000

1312 Zone 3 heating setpoint

°C

Heating general settings

2000

2021 Number of days to next service

365

Days

2000

2022

Service reminder

This function reminds the user of the need to carry out a pro-

grammed service on the boiler, after the number of days set in 

Par. 2021

0 = Deactivates the function

1 = Activates the function

2 = Resets the countdown of days to next service to zero

0…2

0

2000

2078

Set service hours countdown

0= Burner’s hours of operation

1 = Boiler’s hours of operation

0…1

0

Содержание ACQUAHOME R BLU

Страница 1: ...ACQUAHOME R BLU USER MANUAL...

Страница 2: ...recautions that must be observed to ensure the trouble free installation and efficient functioning of your ACQUAHOME R BLU boiler Please accept our renewed thanks for your purchase Thermital CONFORMIT...

Страница 3: ...ety and control devices 5 System layout 6 Control panel 7 Menu navigation 9 Navigation scheme 11 List of user parameters 12 USE 14 Putting into service 14 Preliminary operations 14 Start up 14 Adjustm...

Страница 4: ...for an extended peri od of time perform the operations described later in this manual b This manual is an integral part of the equipment and therefore must be stored carefully and must ALWAYS ac compa...

Страница 5: ...old of 110 C Safety valve intervenes if the boiler pressure exceeds the limit threshold of 3 bar Pressure transducer sends a signal to the electron ic regulator which views and continually checks the...

Страница 6: ...valve 2 Main switch 3 Central heating flow 4 Central heating return 5 Control panel 6 Heating expansion reservoir 7 Burner 8 Drain cock 9 Pump 10 Flame inspection window 11 Boiler body 12 Serial numbe...

Страница 7: ...g the operation after a stop due to an anomaly 5 Navigation keys 6 Main switch located on the equipment rear wall Light Guide displaying STATUS DESCRIPTION Green blinking Thermal unit drain cycle and...

Страница 8: ...e Installer menu 4 Icon displayed when the burner of the equipment is on The icon will be marked with a cross in case of Permanent or Temporary error 5 Icon displayed when the climatic mode operation...

Страница 9: ...setpoint when active available 3 Raise the DHW set point when available 4 Decrease the DHW set point when available 5 ENTER RESET Enters into MENU mode If pressed for more than 5 seconds it resets a p...

Страница 10: ...de keys have the following functions Nr Button Function 1 Exits from the menu and cancels a parameter change 2 Exits from the menu and cancels a parameter change 3 Selects the following menu or increa...

Страница 11: ...11 11 ENGLISH Navigation scheme Modalit visualizzazione base Modalit utente Bar C oppure Example of parameter setting change confirmed change canceled or or or...

Страница 12: ...operation 0 1 0 Info menu 1000 1001 CH flow temperature C 1000 1002 Domestic hot water temperature C 1000 1003 Domestic cold water temperature This parameter is only visible with Par 2035 10 C 1000 10...

Страница 13: ...the setpoint BT Par 2221 45 AT Par 2221 Par 2024 70 AT 45 BT C 2000 2230 Parallel shift of direct Zone Zone 1 climatic curve 10 10 0 C Zone 3 Heating Settings 2000 2303 Zone 3 heating setpoint in 0 an...

Страница 14: ...the thermal unit Bar C close the system load valve Start up Once you have completed all the checks listed above pro ceed as follows to start up the boiler for the first time set the main switch of th...

Страница 15: ...e of the heating temperature setpoint C Increase or decrease the setpoint according to the type of system by using the key of To save the modification made and go back to the initial screen wait for 3...

Страница 16: ...ed only when the external temperature is 10 C Venting The function is automatically enabled at the first start up and at each reset of the power supply When the function is active the message Air is d...

Страница 17: ...Please remember that THE PERSON RESPONSIBLE FOR SYSTEM MANAGEMENT MUST ENSURE THAT PROFES SIONALLY QUALIFIED HEATING ENGINEERS UNDERTAKE PERIODIC MAINTENANCE AND COMBUSTION EFFICIENCY MEASUREMENTS T...

Страница 18: ...Technical Assistan ce Centre The generator triggers a thermal safe ty block Safety thermostat delivery overtemper ature Contact your local Technical Assistan ce Centre No water Contact your local Tec...

Страница 19: ...cycle safely remove the components and dispose of them in a responsible manner in compliance with the installation country s applicable environmental legislation b Adequate sorted waste collection pr...

Страница 20: ...lade Riello 7 37045 Legnago VR www thermital it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are ther...

Отзывы: