Warnings

The text “AttE” is displayed together with the alert number.

The equipment is not locked out, but its functions may be lim-

ited (according to the alert).

Contact your local Technical Assistance Centre

Temporary or short-term shut-down

In the event of temporary or short-term shut-down (e.g. due to 

holidays), proceed as follows:

- Remove the power supply by setting the main switch 

of the equipment and the main switch of the system to 

"OFF".

- If there is a danger of frost, keep the system on. To re-

duce fuel consumption, set the heating set point to the 

minimum allowed value.

Preparing for extended periods of disuse

If the appliance is not going to be used for a long period of 

time, the following operations should be carried out:

set the main switch of the system to OFF and the main switch 

of the equipment to (0);

- close the fuel cock and heating circuit water cock.

Drain the central heating circuit if there is any risk of 

freezing.

Device cleaning and maintenance

Please remember that THE PERSON RESPONSIBLE FOR 

SYSTEM MANAGEMENT MUST ENSURE THAT PROFES-

SIONALLY QUALIFIED HEATING ENGINEERS UNDERTAKE 

PERIODIC MAINTENANCE AND COMBUSTION EFFICIENCY 

MEASUREMENTS.

T

’s Technical Assistance Centre is qualified to 

satisfy these legal requirements and can also provide useful 

information on MAINTENANCE PROGRAMMES designed to 

guarantee:

- Greater safety

- Compliance with applicable legislation

- Freedom from the risk of fines in the event of spot 

checks.

Regular maintenance is essential for the safety, efficiency and 

durability of the boiler.

Servicing is a legal requirement and must be performed at 

least once a year by a professionally qualified heating engi-

neer.

External cleaning

Clean the boiler’s casing panels and control panel with a soft 

cloth damped in soapy water.

To remove marks from the boiler casing, use a cloth damped in 

a 50% mix of water and denatured alcohol or a suitable clean-

ing product.

Wipe the boiler dry after cleaning it.

Do not use abrasive products, petrol or triethylene.

Annual cleaning

At least once a year, the user must have the boiler served by 

T

's Technical Assistance Service or by a qualified 

heating engineer.

Содержание ACQUAHOME R BLU

Страница 1: ...ACQUAHOME R BLU USER MANUAL...

Страница 2: ...recautions that must be observed to ensure the trouble free installation and efficient functioning of your ACQUAHOME R BLU boiler Please accept our renewed thanks for your purchase Thermital CONFORMIT...

Страница 3: ...ety and control devices 5 System layout 6 Control panel 7 Menu navigation 9 Navigation scheme 11 List of user parameters 12 USE 14 Putting into service 14 Preliminary operations 14 Start up 14 Adjustm...

Страница 4: ...for an extended peri od of time perform the operations described later in this manual b This manual is an integral part of the equipment and therefore must be stored carefully and must ALWAYS ac compa...

Страница 5: ...old of 110 C Safety valve intervenes if the boiler pressure exceeds the limit threshold of 3 bar Pressure transducer sends a signal to the electron ic regulator which views and continually checks the...

Страница 6: ...valve 2 Main switch 3 Central heating flow 4 Central heating return 5 Control panel 6 Heating expansion reservoir 7 Burner 8 Drain cock 9 Pump 10 Flame inspection window 11 Boiler body 12 Serial numbe...

Страница 7: ...g the operation after a stop due to an anomaly 5 Navigation keys 6 Main switch located on the equipment rear wall Light Guide displaying STATUS DESCRIPTION Green blinking Thermal unit drain cycle and...

Страница 8: ...e Installer menu 4 Icon displayed when the burner of the equipment is on The icon will be marked with a cross in case of Permanent or Temporary error 5 Icon displayed when the climatic mode operation...

Страница 9: ...setpoint when active available 3 Raise the DHW set point when available 4 Decrease the DHW set point when available 5 ENTER RESET Enters into MENU mode If pressed for more than 5 seconds it resets a p...

Страница 10: ...de keys have the following functions Nr Button Function 1 Exits from the menu and cancels a parameter change 2 Exits from the menu and cancels a parameter change 3 Selects the following menu or increa...

Страница 11: ...11 11 ENGLISH Navigation scheme Modalit visualizzazione base Modalit utente Bar C oppure Example of parameter setting change confirmed change canceled or or or...

Страница 12: ...operation 0 1 0 Info menu 1000 1001 CH flow temperature C 1000 1002 Domestic hot water temperature C 1000 1003 Domestic cold water temperature This parameter is only visible with Par 2035 10 C 1000 10...

Страница 13: ...the setpoint BT Par 2221 45 AT Par 2221 Par 2024 70 AT 45 BT C 2000 2230 Parallel shift of direct Zone Zone 1 climatic curve 10 10 0 C Zone 3 Heating Settings 2000 2303 Zone 3 heating setpoint in 0 an...

Страница 14: ...the thermal unit Bar C close the system load valve Start up Once you have completed all the checks listed above pro ceed as follows to start up the boiler for the first time set the main switch of th...

Страница 15: ...e of the heating temperature setpoint C Increase or decrease the setpoint according to the type of system by using the key of To save the modification made and go back to the initial screen wait for 3...

Страница 16: ...ed only when the external temperature is 10 C Venting The function is automatically enabled at the first start up and at each reset of the power supply When the function is active the message Air is d...

Страница 17: ...Please remember that THE PERSON RESPONSIBLE FOR SYSTEM MANAGEMENT MUST ENSURE THAT PROFES SIONALLY QUALIFIED HEATING ENGINEERS UNDERTAKE PERIODIC MAINTENANCE AND COMBUSTION EFFICIENCY MEASUREMENTS T...

Страница 18: ...Technical Assistan ce Centre The generator triggers a thermal safe ty block Safety thermostat delivery overtemper ature Contact your local Technical Assistan ce Centre No water Contact your local Tec...

Страница 19: ...cycle safely remove the components and dispose of them in a responsible manner in compliance with the installation country s applicable environmental legislation b Adequate sorted waste collection pr...

Страница 20: ...lade Riello 7 37045 Legnago VR www thermital it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are ther...

Отзывы: