GENERAL INFORMATION

General Safety Information

This product must be installed by a legally qualified heat-

ing engineer. On completion of the installation, the install-

er must issue the owner with a declaration of conformity 

confirming that the installation has been completed to 

the highest standards in compliance with the instructions 

provided by 

T

 in this instruction manual, and 

that it conforms to all applicable laws and standards.

This product must only be used for the purpose for which 

it is designed and made, as specified by 

T

T

 declines all responsibility, contractual or 

other, for damage to property or injury to persons or ani-

mals caused by improper installation, adjustment, main-

tenance or use.

The room where the boiler is installed must be properly 

ventilated to ensure a sufficient supply of air for correct 

combustion.

If you notice any water leaks, disconnect the boiler from 

the mains electricity supply and shut off the water supply.

In case of water leaks disconnect the equipment from 

the power mains, close the water supply and promptly 

alert Technical Assistance Centre 

T

 or pro-

fessionally qualified personnel.

The boiler must be serviced at least once a year. The 

failure to perform annual maintenance work will void the 

warranty of the equipment.

Periodically check that pressure in the central heating 

circuit, when cold, is approximately 1.5 bar and be-

low the maximum limit specified for the boiler. If this is 

not the case, contact the Technical Assistance Centre 

T

 or professionally qualified personnel.

If the boiler is not going to be used for an extended peri-

od of time, perform the operations described later in this 

manual.

This manual is an integral part of the equipment and 

therefore must be stored carefully and must ALWAYS ac-

company the boiler even if it is sold to another Owner or 

User or transferred to another plant. If it is damaged or 

lost, request another copy from your local Technical As-

sistance Centre 

T

.

Precautions

The operation of any appliance that uses fuel, electrical power 

and water demands that a number of fundamental safety pre-

cautions be respected:

Do not allow children or infirm persons to operate the 

system unsupervised.

It is forbidden to use electrical devices or equipment, 

such as switches, appliances, etc. if there is a smell of 

gas or un-burnt products. If so:

- Ventilate the room, opening doors and windows

- Close the fuel shut-off cock

- Ask for the prompt intervention of the Technical Assis-

tance Centre

Do not touch the boiler while barefoot or wet.

Never pull, disconnect, or twist the electrical cables com-

ing from the appliance even if it is disconnected from the 

mains electricity supply.

Do not obstruct or restrict the vents in the room where 

the boiler is installed. Adequate ventilation is essential for 

correct combustion.

Do not expose the boiler to the elements. It is not de-

signed for use outdoors.

It is prohibited to leave inflammable substances and con-

tainers in the room where the boiler is installed.

Do not dispose of packaging material into the environ-

ment, or leave it within the reach of children, since it can 

become a potential hazard. Dispose of packaging mate-

rial in compliance with applicable legislation.

It is forbidden to operate the boiler without water.

The equipment casing must not be removed by people 

without specific qualification and expertise.

Содержание ACQUAHOME R BLU

Страница 1: ...ACQUAHOME R BLU USER MANUAL...

Страница 2: ...recautions that must be observed to ensure the trouble free installation and efficient functioning of your ACQUAHOME R BLU boiler Please accept our renewed thanks for your purchase Thermital CONFORMIT...

Страница 3: ...ety and control devices 5 System layout 6 Control panel 7 Menu navigation 9 Navigation scheme 11 List of user parameters 12 USE 14 Putting into service 14 Preliminary operations 14 Start up 14 Adjustm...

Страница 4: ...for an extended peri od of time perform the operations described later in this manual b This manual is an integral part of the equipment and therefore must be stored carefully and must ALWAYS ac compa...

Страница 5: ...old of 110 C Safety valve intervenes if the boiler pressure exceeds the limit threshold of 3 bar Pressure transducer sends a signal to the electron ic regulator which views and continually checks the...

Страница 6: ...valve 2 Main switch 3 Central heating flow 4 Central heating return 5 Control panel 6 Heating expansion reservoir 7 Burner 8 Drain cock 9 Pump 10 Flame inspection window 11 Boiler body 12 Serial numbe...

Страница 7: ...g the operation after a stop due to an anomaly 5 Navigation keys 6 Main switch located on the equipment rear wall Light Guide displaying STATUS DESCRIPTION Green blinking Thermal unit drain cycle and...

Страница 8: ...e Installer menu 4 Icon displayed when the burner of the equipment is on The icon will be marked with a cross in case of Permanent or Temporary error 5 Icon displayed when the climatic mode operation...

Страница 9: ...setpoint when active available 3 Raise the DHW set point when available 4 Decrease the DHW set point when available 5 ENTER RESET Enters into MENU mode If pressed for more than 5 seconds it resets a p...

Страница 10: ...de keys have the following functions Nr Button Function 1 Exits from the menu and cancels a parameter change 2 Exits from the menu and cancels a parameter change 3 Selects the following menu or increa...

Страница 11: ...11 11 ENGLISH Navigation scheme Modalit visualizzazione base Modalit utente Bar C oppure Example of parameter setting change confirmed change canceled or or or...

Страница 12: ...operation 0 1 0 Info menu 1000 1001 CH flow temperature C 1000 1002 Domestic hot water temperature C 1000 1003 Domestic cold water temperature This parameter is only visible with Par 2035 10 C 1000 10...

Страница 13: ...the setpoint BT Par 2221 45 AT Par 2221 Par 2024 70 AT 45 BT C 2000 2230 Parallel shift of direct Zone Zone 1 climatic curve 10 10 0 C Zone 3 Heating Settings 2000 2303 Zone 3 heating setpoint in 0 an...

Страница 14: ...the thermal unit Bar C close the system load valve Start up Once you have completed all the checks listed above pro ceed as follows to start up the boiler for the first time set the main switch of th...

Страница 15: ...e of the heating temperature setpoint C Increase or decrease the setpoint according to the type of system by using the key of To save the modification made and go back to the initial screen wait for 3...

Страница 16: ...ed only when the external temperature is 10 C Venting The function is automatically enabled at the first start up and at each reset of the power supply When the function is active the message Air is d...

Страница 17: ...Please remember that THE PERSON RESPONSIBLE FOR SYSTEM MANAGEMENT MUST ENSURE THAT PROFES SIONALLY QUALIFIED HEATING ENGINEERS UNDERTAKE PERIODIC MAINTENANCE AND COMBUSTION EFFICIENCY MEASUREMENTS T...

Страница 18: ...Technical Assistan ce Centre The generator triggers a thermal safe ty block Safety thermostat delivery overtemper ature Contact your local Technical Assistan ce Centre No water Contact your local Tec...

Страница 19: ...cycle safely remove the components and dispose of them in a responsible manner in compliance with the installation country s applicable environmental legislation b Adequate sorted waste collection pr...

Страница 20: ...lade Riello 7 37045 Legnago VR www thermital it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are ther...

Отзывы: