34
ENGLISH
INSTALLER
b
Maximum straight length is the maximum length of
the flue without bends, terminals or joints.
b
Values referred to atmospheric pressure at sea
level.
b
Maximum straight length is the maximum length of
the flue without bends, terminals or joints.
b
Values referred to atmospheric pressure at sea
level.
Coaxial flues (Ø 80/125)
An adapter kit must be used in order to install this size of
flue. Coaxial flues can be oriented in whatever direction
is most convenient for the room, provided the maximum
lengths specified alongside are respected.
b
Use only flues specifically designed for use with
condensing boilers. Follow the instructions pro-
vided in the flue pipe kit to install the flues.
Twin flues (Ø 80)
Twin flues can be oriented in whatever direction is most
convenient for the room.
b
Ensure that the flue gas vent pipe has a 1% slope
towards the boiler.
b
Use of flues longer than the maximum specified
alongside leads to a loss of heat output from the
boiler (see table alongside).
b
The boiler automatically adapts its ventilation sys-
tem to suit the type of installation and the length of
the flue. Never obstruct or partly choke the combu-
rent air intake pipe.
b
Use only flues specifically designed for use with
condensing boilers. Follow the instructions pro-
vided in the flue pipe kit to install the flues.
Unscrew the screws and remove the cover from the air
intake (A), and connect the comburent air pipe to it.
Connect the vent pipe to the flue gas outlet (B).
If the flue pipes used differ in length from those shown in
the table, make sure that the total length does not exceed
100 metres for model 20/200 SOL E and 60 metres for
model 30/200 SOL E and, that the maximum length of
each individual pipe section does not exceed 50 metres
for model 20/200 SOL E and 30 metres for model 30/200
SOL E.
Maximum straight length of
coaxial flue Ø 80/125 (m)
Pressure drop (m)
45° bend 90° bend
14,85
0,5
0,85
Maximum straight length of
twin flues Ø 80 (m)
Pressure drop (m)
45° bend 90° bend
50+50 (20/200 SOL)
0,5
0,8
30+30 (30/200 SOL)
0,5
0,8
B
A
2040 60
80
100
4
3
2 1 0
0
120