1. Press start screen to open Menu screen.
2. Press
3. Press
to show heating settings.
4. Make the desired changes.
5. Confirm settings by pressing
Important! If your house has under floor heating and heat sensitive floors, the supply line temperature must not exceed certain temper-
atures. Otherwise the floor might get damaged.
8.1.7
Adjusting the indoor temperature
Comfort adjustment, to change temperature (heating mode)
On the start screen, "comfort adjustment" of the indoor temperature may be done very easily. Provided that the heat curve is set proper-
ly.
11:20
20 ˚C
Press
or
, alternatively drag clockwise or anticlockwise to raise or lower the temperature.
Each step represents an increase/decrease of approximately 1°C of the indoor temperature depend-
ing on comfort factor settings.
8.1.8
Additional information about heating settings
11:20
20
17
10
5
0
-5
-15
-25
40
80
60
21
29
34
40
44
+1
51
59
Auto
supply line (˚C)
outdoor (˚C)
1. Press start screen to open Menu screen.
2. Press
3. Press
to show the heat curve graph.
4. Press
to show other heating settings.
The heat curve is the base for all space heating adjustments. The curve number (example "40") corresponds to what target temperature
the supply line will have to the heating system when the outdoor temperature is 0 °C (if not adjusted with any offset). A higher set heat
curve will increase the desired supply line temperature when the outdoor temperature gets lower and vice versa.
Enable heating is default on, and should normally never be deactivated as this will stop heating (risk of freezing).
Start with setting Heating type (Radiator/floor heating) . Floor heating will limit max adjustable supply line temperature for end cus-
tomer to 45°C for installations with floor heating . Floor heating will also set the default heat curve to «30» instead of 40. Note that the
value for the heat curve should be adjusted and fine tuned for the installation to get desired indoor climate.
Supply line minimum is the minimum supply line temperature used as base line for the heat curve.
Installation Guide
Calibra Cool
Thermia AB
BWCC01IG0102
27
Содержание Calibra Cool
Страница 1: ...Installation Guide Calibra Cool BW WW models www thermia com...
Страница 40: ...Installation Guide Calibra Cool BWCC01IG0102 Thermia AB 40...
Страница 41: ...Installation Guide Calibra Cool Thermia AB BWCC01IG0102 41...
Страница 42: ...Installation Guide Calibra Cool BWCC01IG0102 Thermia AB 42...
Страница 43: ...Installation Guide Calibra Cool Thermia AB BWCC01IG0102 43...