background image

3

Transportation, space requirement and Recommended location

3.1

Transportation

The heat pump must not be transported lying down!

 

 

Max 45

Maximum tilt 45 °

 

 

Calibra Cool

 

157-169 kg!

 

Installation Guide

Calibra Cool

Thermia AB

BWCC01IG0102

11

Содержание Calibra Cool

Страница 1: ...Installation Guide Calibra Cool BW WW models www thermia com...

Страница 2: ...anty if these instructions are not adhered to during installation or service The English language is used for the original instructions Other languages are a translation of the original instructions D...

Страница 3: ...power supply 20 6 2 Outdoor sensor 20 6 3 Power supply 400V 21 6 4 External reversing valve Optional 21 6 5 Fuse sizes 400V 22 7 Filling and bleeding 23 7 1 Filling and bleeding the brine circuit 23...

Страница 4: ...cessories functions etc 38 10 Electrical connections 39 10 1 Calibra Cool electrical connections 400V this label is also fitted on the electrical cabinet of the heat pump 39 Installation Guide Calibra...

Страница 5: ...sk of personal injury Indicates a possible danger that can lead to fatal or serious injury if necessary measures are not taken Caution Risk of installation damage Indicates a possible hazard that can...

Страница 6: ...conditions with regards to hard water a softening filter may be necessary to use install The softening filter softens the water cleans any impurities and prevents the buildup of calcification The hot...

Страница 7: ...e is used for the collector circuit vertical horizontal In most applications a T 3 5 K is desired for most efficient running The lengths of the collectors are based on ethanol 30 at 0 C PEM40 Calibra...

Страница 8: ...show ing BW model WW model does not include filling device and level vessel for cold carrier 3a 1 Alternative 1 heating and cooling distributed to the same system not recommended to normal convection...

Страница 9: ...ng Cooling system supply pipe 28 mm 4 Heating Cooling system return pipe 28 mm 5 Connection for bleed valve 28 mm 6 Hot water line 22 mm 7 Cold water line 22 mm 8 Lead in for supply sensor and communi...

Страница 10: ...pressure not included in delivery Outdoor sensor Filter ball heating system Cable inlets Document holder Grommets 28 Tube insulation Plastic cap Filling device brine WW version Filter ball Level vess...

Страница 11: ...space requirement and Recommended location 3 1 Transportation The heat pump must not be transported lying down Max 45 Maximum tilt 45 Calibra Cool 157 169 kg Installation Guide Calibra Cool Thermia AB...

Страница 12: ...r near a bedroom The surrounding walls can amplify the sound from the heat pump 1930 mm 5 C OK 30 C 300 mm 300 mm 300 mm 10 mm 600 mm x4 1 2 3 Adjust the heat pump using the adjustable feet so that it...

Страница 13: ...mplify the removal The heat pump should be placed on a stable floor with a floor well so any condensation may drain from the condensation hole in the bottom of the heat pump preferably a concrete floo...

Страница 14: ...l 86 Safety valve Max 3 bar heat pump recommended 1 5 bar 87 Safety valve 9 bar hot water 91 Dirt strainer with shut off valve DN 25 113 Expansion vessel Make sure that a free flow is always possible...

Страница 15: ...nt or the thermic expansion of the brine is expected to exceed the volume of the vessel it should be considered to install a pressure ves sel instead Picture showing a common layout for BW model of fi...

Страница 16: ...ure it reaches the 32 mm mark To disassemble if required 1 Push the plastic ring inwards 2 Pull the pieces apart 1 2 Insulate the brine pipe and prepare with the insulation tape before installing the...

Страница 17: ...pipes 3 Install the insulated pipes from the inside of the heat pump and out Pay attention to which one of the pipes are brine in and brine out see picture below 4 Press the pipes on to the connection...

Страница 18: ...e pipes on to the connections in the heat pump see picture below Install the insulated pipes from the inside of the heat pump and out Pay attention to which one of the pipes are brine in and brine out...

Страница 19: ...ipes 3 Press the pipes on to the connections in the heat pump see picture below Install the insulated pipes from the inside of the heat pump and out Pay attention to which one of the pipes are brine i...

Страница 20: ...must be disconnected before electrical installation can commence 400V version Calibra Cool complies with IEC 61000 3 12 without conditional connection 6 2 Outdoor sensor 50 m 0 75 mm2 50 120 m 1 5 mm...

Страница 21: ...xternal reversing valve Optional In systems with separated cooling circuit a reversing valve can be fitted outside the heat pump For connection on to the heat pump see chapter Electrical connections t...

Страница 22: ...rent of compressor 12 A at 230V nominal The picture below shows the actual current consumption with the recommended fuse size shown in brackets 400V 3N 50 Hz fuse C curve Calibra Cool I max Fuse 13A 1...

Страница 23: ...1 Fill the water heater with cold water by opening the shut off valve on the incoming cold water pipe Open one of the hot water taps in the house 2 Then fill the water heater coil and the heating sys...

Страница 24: ...ut off valve 94 Filling device 100 Safety valve 121 Brine in 122 Brine out A Shut off valve part of 94 B Shut off valve part of 94 C Dirt strainer with shut off valve part of 94 D External container E...

Страница 25: ...art screen 2 Press 3 Press on the text Language 4 Select language 5 Press to return to System settings Or press in the upper left corner to return to the Menu screen 8 1 2 Setting date and time 1 Pres...

Страница 26: ...he Curve indicator symbol 11 20 20 17 10 5 0 5 15 25 40 80 60 21 29 34 40 44 1 51 59 Auto supply line C outdoor C 1 Press on the Start screen to open the Menu screen 2 Press 3 Press if the Heat curve...

Страница 27: ...creen to open Menu screen 2 Press 3 Press to show the heat curve graph 4 Press to show other heating settings The heat curve is the base for all space heating adjustments The curve number example 40 c...

Страница 28: ...ith 1 C step Note Fixed supply line set point that may be available in the menu is not used in normal installations and should normally not be activated The heat curve shows the desired supply line te...

Страница 29: ...hows that the heat curve window is active This window is the default window Shows that the heating settings window is inactive Press on the symbol to open heating set tings Shows that the heating sett...

Страница 30: ...ay apply if external devices are installed and activated After completion of the test close manual test Parameter Meaning Circulation pump 0 stop circulation pump 1 start circulation pump Brine pump o...

Страница 31: ...trical power to the heat pump when the compressor is running When planned set the operating mode to off position and allow compressor to stop completely before shutting off the electrical power to the...

Страница 32: ...tart screen to open the Menu screen 2 Press on Settings 3 Press on the text Heat pump 4 Navigate to Brine in monitoring 5 Set desired minimum temperature 6 Press to activate 7 Confirm settings by pres...

Страница 33: ...two criteria shall be met Cooling season Indoor temperature exceeds the desired indoor temperature for heating temperature on start page the set value for Passive cooling room sensor offset default 2...

Страница 34: ...eat pump 8 8 Selecting hot water settings Hot water settings The hot water production is activated from factory but the setting the customers hot water mode can be selected during commission ing 1 Go...

Страница 35: ...on equipment switched on Activation deactivation of push pull control or switch functions equipment on off Press on the symbol to change mode The symbol indicates deactivated function equipment switch...

Страница 36: ...heat pump is in space heating mode Restriction timer Visible in the top of the display when the heat pump is in restriction to start Tap water mode Visible in the top of the display when the heat pum...

Страница 37: ...h soft ware 10 01 only inbuilt passive cooling Buffer tank is not supported in soft ware 10 01 Functionality Calibra Cool Connections Position num bers used Remark Room sensor PT1000 type BM T31 132 R...

Страница 38: ...ou enable a function you enable the different functions in a similar way 1 Login 607080 2 Go to SETTINGS INSTALLATION and select desired function Activate by selecting BM if function is connected to B...

Страница 39: ...t exchanger Hot Water Supply line Borehole return line Return line Heat pump refrigerant circuit BW models BW models WW models Space heating or cooling Cooling mode Cooling mode Heating mode Heating m...

Страница 40: ...Installation Guide Calibra Cool BWCC01IG0102 Thermia AB 40...

Страница 41: ...Installation Guide Calibra Cool Thermia AB BWCC01IG0102 41...

Страница 42: ...Installation Guide Calibra Cool BWCC01IG0102 Thermia AB 42...

Страница 43: ...Installation Guide Calibra Cool Thermia AB BWCC01IG0102 43...

Страница 44: ...rial Thermia reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes being neces...

Отзывы: