4
Heating connections
4.1
Calibra Cool
85
85
86
85
1
113
91
12
13
80
81
87
11
10
75
1
Heat pump
10
Heating/Cooling system supply pipe
11
Heating/Cooling system return pipe
12
Cold water line
13
Hot water line
75
Mixer valve hot water, with exchange valve
80
Shut-off valve
81
Filling valve (Check for local regulations when installing filling valve)
85
Venting valve (hot water tank coil)
86
Safety valve (Max 3 bar, heat pump), recommended: 1,5 bar
87
Safety valve (9 bar, hot water)
91
Dirt strainer with shut-off valve, DN 25
113
Expansion vessel
Make sure that a free flow is always possible on the heating circuit. Very small water volumes or stop in the heating circuit may cause
operational disturbances.
Caution
As the water temperature becomes hot, a mixer valve must be instal-
led between the cold water and the hot water pipes to ensure a lower
domestic hot temperature. Consider local and national requirements.
Installation Guide
Calibra Cool
BWCC01IG0102
Thermia AB
14